#PDB cf residue atom bb_p bb_s bb_f chi_p chi_s HB-D HB-I REF pred #--------------------------------------------------------------------------------------------- 2gwp n LEU 2 N 0.00 0.00 -4.62 0.99 4.77 -1.26 -4.81 117.00 112.07 2gwp n LEU 2 Ca 0.00 0.00 -0.43 0.00 -0.03 0.00 0.00 56.01 55.55 2gwp n LEU 2 Cb 0.00 0.00 -0.03 0.00 -2.33 0.00 0.00 43.42 41.06 2gwp n LEU 2 CO 0.00 0.00 1.50 -0.76 -1.33 0.00 0.00 177.39 176.80 2gwp s LEU 3 N 0.00 3.74 0.27 2.23 1.02 -1.26 -4.93 118.68 119.75 2gwp s LEU 3 Ca 0.00 1.61 -0.05 0.00 0.02 0.00 0.00 54.13 55.71 2gwp s LEU 3 Cb 0.00 -3.53 -0.01 0.00 0.02 0.00 0.00 46.19 42.67 2gwp s LEU 3 CO 0.00 -1.48 0.38 0.00 0.02 0.00 0.00 176.35 175.27 2gwp s TYR 5 N -3.73 -0.54 0.11 0.00 -0.85 0.93 -4.90 117.35 108.38 2gwp s TYR 5 Ca 0.30 0.64 -0.15 0.00 -0.52 0.00 0.00 57.07 57.34 2gwp s TYR 5 Cb 0.02 0.49 -0.07 0.00 0.38 0.00 0.00 41.96 42.78 2gwp s TYR 5 CO 0.14 -0.66 0.52 0.00 -1.52 0.00 0.00 175.55 174.03 2gwp s ARG 7 N -1.69 0.49 -0.17 0.00 6.06 -0.34 -4.95 118.95 118.35 2gwp s ARG 7 Ca 0.34 -0.12 -0.14 0.00 -2.50 0.00 0.00 55.73 53.30 2gwp s ARG 7 Cb -0.16 0.21 -0.04 0.00 0.06 0.00 0.00 34.95 35.02 2gwp s ARG 7 CO 0.18 -0.11 0.32 0.21 -2.50 0.00 0.00 175.30 173.40 2gwp s LYS 8 N -0.94 4.25 0.00 5.12 2.20 -1.26 0.60 119.74 129.71 2gwp s LYS 8 Ca -0.10 0.12 0.00 0.00 -0.36 0.00 0.00 55.97 55.63 2gwp s LYS 8 Cb -0.05 -3.45 0.00 0.00 -1.51 0.00 0.00 37.83 32.82 2gwp s LYS 8 CO 0.02 0.18 0.00 0.41 -0.36 0.00 0.00 175.35 175.60 2gwp n GLY 9 N 3.51 2.42 0.00 5.54 0.00 -0.35 -4.91 105.19 111.40 2gwp n GLY 9 Ca -0.11 -0.49 0.00 0.00 0.00 0.00 0.00 46.02 45.42 2gwp n GLY 9 CO 0.00 0.00 0.00 -2.39 0.00 0.00 0.00 173.32 170.93 2gwp n HIS 10 N 0.00 0.00 -0.62 1.61 1.44 -1.26 -4.91 115.22 111.47 2gwp n HIS 10 Ca 0.00 0.00 -0.29 0.00 -2.01 0.00 0.00 57.72 55.42 2gwp n HIS 10 Cb 0.00 0.00 0.25 0.00 0.12 0.00 0.00 29.99 30.36 2gwp n HIS 10 CO 0.00 0.00 0.00 0.00 -2.81 0.00 0.00 176.34 173.53 2gwp s LYS 12 N -4.64 1.88 -0.38 0.00 1.02 -1.26 -4.84 119.74 111.52 2gwp s LYS 12 Ca 0.68 1.36 -0.27 0.00 0.02 0.00 0.00 55.97 57.77 2gwp s LYS 12 Cb -0.22 -1.84 -0.05 0.00 -0.52 0.00 0.00 37.83 35.20 2gwp s LYS 12 CO 0.63 -1.96 2.25 0.50 -0.92 0.00 0.00 175.35 175.85 2gwp s ARG 13 N -4.67 2.63 0.00 1.68 3.52 -1.26 -1.30 118.95 119.55 2gwp s ARG 13 Ca 0.65 1.60 0.00 0.00 -0.13 0.00 0.00 55.73 57.84 2gwp s ARG 13 Cb -0.20 -4.46 0.00 0.00 -1.56 0.00 0.00 34.95 28.73 2gwp s ARG 13 CO 0.54 -2.68 0.00 0.41 -0.81 0.00 0.00 175.30 172.77 2gwp n GLY 14 N 5.85 0.86 0.00 8.12 0.00 -1.26 -5.09 105.19 113.66 2gwp n GLY 14 Ca 0.32 -0.14 0.00 0.00 0.00 0.00 0.00 46.02 46.20 2gwp n GLY 14 CO 0.00 0.00 0.00 1.22 0.00 0.00 0.00 173.32 174.54 2gwp n ASP 15 N 0.26 0.00 -4.14 1.61 9.92 -0.42 -4.82 116.55 118.95 2gwp n ASP 15 Ca 0.00 -0.40 -0.33 0.00 -0.53 0.00 0.00 54.79 53.53 2gwp n ASP 15 Cb 0.00 0.00 -0.16 0.00 -0.64 0.00 0.00 41.12 40.32 2gwp n ASP 15 CO 0.00 0.00 0.00 -0.13 0.13 0.00 0.00 177.20 177.20 2gwp s ARG 16 N -0.63 3.00 0.14 -1.24 1.81 -0.45 -4.97 118.95 116.62 2gwp s ARG 16 Ca 0.00 -0.84 -0.27 0.00 -1.72 0.00 0.00 55.73 52.91 2gwp s ARG 16 Cb 0.00 -2.53 -0.07 0.00 -0.45 0.00 0.00 34.95 31.90 2gwp s ARG 16 CO 0.00 -0.14 0.83 0.08 -0.68 0.00 0.00 175.30 175.39 2gwp s VAL 17 N 1.13 4.43 -0.04 3.52 1.01 -1.26 -0.14 120.40 129.04 2gwp s VAL 17 Ca 0.01 1.81 0.01 0.00 0.00 0.00 0.00 61.98 63.80 2gwp s VAL 17 Cb -0.14 -4.19 -0.03 0.00 0.00 0.00 0.00 36.38 32.02 2gwp s VAL 17 CO -0.09 0.45 -0.03 0.54 0.00 0.00 0.00 175.10 175.97 2gwp n ARG 18 N 2.06 0.60 0.00 2.72 5.12 0.80 -4.91 116.66 123.05 2gwp n ARG 18 Ca -0.03 0.02 0.00 0.00 -1.93 0.00 0.00 57.85 55.91 2gwp n ARG 18 Cb 0.49 -1.08 0.00 0.00 -1.16 0.00 0.00 32.46 30.70 2gwp n ARG 18 CO 0.00 0.00 0.00 0.41 -1.93 0.00 0.00 177.63 176.11 2gwp n GLY 19 N 3.23 -0.69 3.91 -0.13 0.00 -0.62 -4.98 105.19 105.90 2gwp n GLY 19 Ca -0.07 -0.44 -0.31 0.00 0.00 0.00 0.00 46.02 45.19 2gwp n GLY 19 CO 0.00 0.00 0.00 -0.51 0.00 0.00 0.00 173.32 172.81 2gwp s THR 20 N -4.00 5.23 -0.07 2.61 -4.23 -1.26 0.21 115.64 114.13 2gwp s THR 20 Ca 0.00 -0.11 -0.02 0.00 -1.18 0.00 0.00 61.69 60.38 2gwp s THR 20 Cb 0.00 -3.63 -0.04 0.00 1.34 0.00 0.00 72.50 70.17 2gwp s THR 20 CO 0.00 0.05 -0.08 0.00 -0.54 0.00 0.00 174.62 174.06 2gwp n GLY 22 N 2.83 1.85 3.57 0.00 0.00 -0.82 -4.95 105.19 107.66 2gwp n GLY 22 Ca -0.13 -0.58 -0.39 0.00 0.00 0.00 0.00 46.02 44.92 2gwp n GLY 22 CO 0.00 0.00 0.00 -0.42 0.00 0.00 0.00 173.32 172.90 2gwp s ILE 23 N -2.05 3.20 -1.18 -0.61 -1.09 -1.26 -1.50 121.20 116.70 2gwp s ILE 23 Ca 0.00 0.16 0.00 0.00 -2.23 0.00 0.00 60.65 58.58 2gwp s ILE 23 Cb 0.00 -3.42 0.00 0.00 -1.58 0.00 0.00 42.46 37.46 2gwp s ILE 23 CO 0.00 -0.36 0.00 0.54 -1.23 0.00 0.00 174.94 173.89 2gwp n ARG 24 N 8.92 -0.85 -5.28 2.79 5.12 -1.26 -5.00 116.66 121.10 2gwp n ARG 24 Ca 0.28 0.82 -0.31 0.00 -1.93 0.00 0.00 57.85 56.71 2gwp n ARG 24 Cb 0.51 -4.86 -0.16 0.00 -1.16 0.00 0.00 32.46 26.79 2gwp n ARG 24 CO 0.00 0.00 0.00 -0.06 -1.93 0.00 0.00 177.63 175.64 2gwp s PHE 25 N -2.48 2.38 0.08 -1.55 0.40 -0.56 -1.22 117.98 115.03 2gwp s PHE 25 Ca 0.00 -0.52 0.08 0.00 -0.60 0.00 0.00 56.93 55.89 2gwp s PHE 25 Cb 0.00 -1.54 -0.04 0.00 0.51 0.00 0.00 43.02 41.95 2gwp s PHE 25 CO 0.00 -0.09 -0.17 -0.51 0.70 0.00 0.00 175.22 175.15 2gwp s LEU 26 N -0.47 2.72 -0.31 -0.37 1.02 0.20 0.03 118.68 121.50 2gwp s LEU 26 Ca 0.06 -0.47 -0.20 0.00 0.02 0.00 0.00 54.13 53.54 2gwp s LEU 26 Cb -0.11 -1.58 -0.01 0.00 0.02 0.00 0.00 46.19 44.51 2gwp s LEU 26 CO 0.01 0.21 0.61 -0.47 0.02 0.00 0.00 176.35 176.73 2gwp s TYR 27 N -1.05 3.20 0.36 0.29 5.04 0.13 -1.20 117.35 124.12 2gwp s TYR 27 Ca 0.17 0.51 0.04 0.00 -2.44 0.00 0.00 57.07 55.34 2gwp s TYR 27 Cb -0.11 -2.99 -0.06 0.00 0.35 0.00 0.00 41.96 39.16 2gwp s TYR 27 CO 0.08 -0.49 0.06 0.00 -1.34 0.00 0.00 175.55 173.86 2gwp s PRO 30 N 1.52 4.79 -0.00 0.00 0.04 -1.23 -1.34 135.00 138.78 2gwp s PRO 30 Ca -0.04 1.54 0.15 0.00 0.04 0.00 0.00 61.00 62.69 2gwp s PRO 30 Cb -0.12 -3.28 -0.16 0.00 0.04 0.00 0.00 34.50 30.98 2gwp s PRO 30 CO -0.04 0.41 0.61 2.89 0.04 0.00 0.00 177.00 180.91 2gwp n ARG 31 N 1.68 2.13 0.00 4.56 1.85 -1.26 -4.91 116.66 120.71 2gwp n ARG 31 Ca -0.01 -0.00 0.00 0.00 -1.00 0.00 0.00 57.85 56.84 2gwp n ARG 31 Cb 0.47 -1.19 0.00 0.00 -1.05 0.00 0.00 32.46 30.69 2gwp n ARG 31 CO 0.00 0.00 0.00 2.89 -0.01 0.00 0.00 177.63 180.51