============================================================================= SHIFTS, version 4.1 [X.-P. Xu and D.A. Case, Mar. 2002] ============================================================================= shifts will be computed for atoms matching ::H* found 9 rings ring int. center anis. iso. TYR 9 0.840 114.469-134.145 109.692 -99.200 -91.000 TYR 38 0.840 122.474-104.871 104.897 -99.200 -91.000 TYR 45 0.840 123.264-118.741 109.620 -99.200 -91.000 PHE 46 1.000 118.808-121.095 110.931 -99.200 -91.000 HIS 62 0.900 120.141-128.223 88.011 -99.200 -91.000 TYR 70 0.840 112.167-115.637 88.178 -99.200 -91.000 TYR 75 0.840 107.842-125.623 98.719 -99.200 -91.000 HIS 102 0.900 110.998-130.851 107.109 -99.200 -91.000 HIS 111 0.900 113.522-111.717 80.913 -99.200 -91.000 ============================================================================= Atom RingCur El P_anis Const RC pred Obs ============================================================================= 3knkW1 MET 1 HA -0.05 -0.07 0.22 -0.75 4.52 3.86 3knkW1 MET 1 HB2 -0.03 -0.01 0.08 -0.04 2.15 2.15 3knkW1 MET 1 HB3 -0.03 -0.02 0.01 -0.04 2.03 1.94 3knkW1 MET 1 HG2 -0.05 0.13 -0.01 -0.04 2.63 2.66 3knkW1 MET 1 HG3 -0.19 -0.05 -0.12 -0.04 2.56 2.16 3knkW1 MET 1 HE3 -0.13 -0.02 0.03 -0.04 2.10 1.95 3knkW1 GLU 2 H -0.10 0.20 0.06 -0.55 8.60 8.21 3knkW1 GLU 2 HA -0.01 0.17 0.79 -0.75 4.29 4.49 3knkW1 GLU 2 HB2 0.02 0.04 -0.10 -0.04 2.09 2.01 3knkW1 GLU 2 HB3 0.02 0.04 -0.19 -0.04 1.99 1.82 3knkW1 GLU 2 HG2 -0.03 -0.05 0.09 -0.04 2.34 2.30 3knkW1 GLU 2 HG3 -0.01 -0.02 -0.06 -0.04 2.34 2.20 3knkW1 ALA 3 H -0.02 0.31 0.18 -0.55 8.40 8.31 3knkW1 ALA 3 HA -0.10 0.12 0.89 -0.75 4.34 4.49 3knkW1 ALA 3 HB3 0.12 0.02 0.00 -0.04 1.41 1.51 3knkW1 LYS 4 H 0.05 0.09 0.18 -0.55 8.42 8.18 3knkW1 LYS 4 HA 0.00 0.19 0.90 -0.75 4.32 4.66 3knkW1 LYS 4 HB2 0.03 -0.03 0.06 -0.04 1.87 1.89 3knkW1 LYS 4 HB3 0.00 0.00 0.15 -0.04 1.79 1.90 3knkW1 LYS 4 HG2 0.02 0.03 -0.13 -0.04 1.46 1.34 3knkW1 LYS 4 HG3 0.02 0.01 -0.03 -0.04 1.46 1.43 3knkW1 LYS 4 HD2 0.02 0.02 -0.01 -0.04 1.69 1.68 3knkW1 LYS 4 HD3 0.06 0.00 -0.07 -0.04 1.68 1.64 3knkW1 LYS 4 HE2 0.04 0.02 -0.04 -0.04 2.99 2.97 3knkW1 LYS 4 HE3 0.04 -0.01 -0.03 -0.04 2.99 2.94 3knkW1 ALA 5 H -0.03 0.36 0.32 -0.55 8.40 8.51 3knkW1 ALA 5 HA -0.01 0.11 0.52 -0.75 4.34 4.21 3knkW1 ALA 5 HB3 -0.02 0.02 -0.05 -0.04 1.41 1.33 3knkW1 ILE 6 H -0.02 0.26 0.16 -0.55 8.25 8.10 3knkW1 ILE 6 HA -0.06 0.23 0.64 -0.75 4.18 4.24 3knkW1 ILE 6 HB -0.03 -0.03 -0.39 -0.04 1.89 1.39 3knkW1 ILE 6 HG12 -0.06 0.01 0.00 -0.04 1.49 1.41 3knkW1 ILE 6 HG13 -0.06 0.20 0.18 -0.04 1.21 1.49 3knkW1 ILE 6 HG23 -0.04 -0.03 -0.22 -0.04 0.93 0.60 3knkW1 ILE 6 HD13 -0.02 -0.03 -0.09 -0.04 0.88 0.70 3knkW1 ALA 7 H -0.03 0.94 0.30 -0.55 8.40 9.06 3knkW1 ALA 7 HA 0.00 0.21 0.87 -0.75 4.34 4.67 3knkW1 ALA 7 HB3 0.01 -0.04 0.12 -0.04 1.41 1.46 3knkW1 ARG 8 H -0.01 0.25 -0.03 -0.55 8.46 8.11 3knkW1 ARG 8 HA 0.03 -0.00 0.91 -0.75 4.34 4.53 3knkW1 ARG 8 HB2 -0.08 0.06 0.05 -0.04 1.90 1.89 3knkW1 ARG 8 HB3 -0.03 0.03 -0.00 -0.04 1.80 1.75 3knkW1 ARG 8 HG2 -0.12 -0.07 -0.14 -0.04 1.67 1.29 3knkW1 ARG 8 HG3 -0.09 0.05 -0.08 -0.04 1.67 1.51 3knkW1 ARG 8 HD2 -0.31 -0.00 -0.00 -0.04 3.22 2.87 3knkW1 ARG 8 HD3 -0.34 -0.01 -0.03 -0.04 3.22 2.80 3knkW1 TYR 9 H 0.46 0.03 0.12 -0.55 8.29 8.35 3knkW1 TYR 9 HA 0.13 -0.08 0.32 -0.75 4.56 4.17 3knkW1 TYR 9 HB2 0.00 0.14 0.03 -0.04 3.06 3.19 3knkW1 TYR 9 HB3 0.02 0.02 0.08 -0.04 2.98 3.06 3knkW1 TYR 9 HD2 -0.05 -0.07 -0.02 -0.04 7.15 6.96 3knkW1 TYR 9 HE2 -0.03 0.01 -0.01 -0.04 6.85 6.78 3knkW1 VAL 10 H 0.04 0.07 0.19 -0.55 8.24 8.00 3knkW1 VAL 10 HA -0.05 0.36 0.88 -0.75 4.13 4.57 3knkW1 VAL 10 HB -0.16 -0.32 0.11 -0.04 2.12 1.71 3knkW1 VAL 10 HG13 -0.65 0.01 -0.28 -0.04 0.97 0.00 3knkW1 VAL 10 HG23 -0.05 0.11 -0.26 -0.04 0.95 0.72 3knkW1 ARG 11 H -0.08 -0.24 0.25 -0.55 8.46 7.84 3knkW1 ARG 11 HA -0.05 0.08 0.33 -0.75 4.34 3.96 3knkW1 ARG 11 HB2 -0.01 0.08 -0.42 -0.04 1.90 1.51 3knkW1 ARG 11 HB3 -0.01 0.03 0.43 -0.04 1.80 2.20 3knkW1 ARG 11 HG2 -0.01 -0.01 -0.04 -0.04 1.67 1.57 3knkW1 ARG 11 HG3 0.01 0.01 0.00 -0.04 1.67 1.65 3knkW1 ARG 11 HD2 0.00 -0.02 -0.01 -0.04 3.22 3.15 3knkW1 ARG 11 HD3 0.01 -0.02 0.07 -0.04 3.22 3.24 3knkW1 ILE 12 H -0.10 0.15 0.33 -0.55 8.25 8.08 3knkW1 ILE 12 HA -0.02 0.16 0.56 -0.75 4.18 4.12 3knkW1 ILE 12 HB -0.23 0.14 -0.26 -0.04 1.89 1.50 3knkW1 ILE 12 HG12 0.01 -0.04 -0.07 -0.04 1.49 1.35 3knkW1 ILE 12 HG13 0.06 0.06 0.06 -0.04 1.21 1.34 3knkW1 ILE 12 HG23 -0.15 -0.05 -0.35 -0.04 0.93 0.34 3knkW1 ILE 12 HD13 0.19 -0.01 -0.13 -0.04 0.88 0.89 3knkW1 SER 13 H -0.01 0.15 0.05 -0.55 8.46 8.11 3knkW1 SER 13 HA -0.03 0.27 0.71 -0.75 4.49 4.68 3knkW1 SER 13 HB2 -0.01 0.07 0.06 -0.04 3.95 4.03 3knkW1 SER 13 HB3 -0.01 -0.10 0.06 -0.04 3.93 3.84 3knkW1 PRO 14 HA -0.01 0.01 0.28 -0.51 4.44 4.21 3knkW1 PRO 14 HB2 -0.02 -0.05 0.11 -0.04 2.28 2.29 3knkW1 PRO 14 HB3 -0.02 0.11 -0.05 -0.04 2.02 2.02 3knkW1 PRO 14 HG2 -0.06 0.01 0.16 -0.04 2.03 2.10 3knkW1 PRO 14 HG3 -0.05 0.12 0.03 -0.04 2.03 2.09 3knkW1 PRO 14 HD2 -0.04 0.07 0.19 -0.04 3.68 3.86 3knkW1 PRO 14 HD3 -0.05 0.33 0.10 -0.04 3.65 3.98 3knkW1 ARG 15 H -0.01 0.17 -0.09 -0.55 8.46 7.98 3knkW1 ARG 15 HA 0.00 0.06 0.33 -0.75 4.34 3.98 3knkW1 ARG 15 HB2 -0.00 -0.05 0.07 -0.04 1.90 1.88 3knkW1 ARG 15 HB3 0.00 0.07 -0.09 -0.04 1.80 1.75 3knkW1 ARG 15 HG2 0.00 0.04 0.04 -0.04 1.67 1.71 3knkW1 ARG 15 HG3 -0.00 -0.02 0.05 -0.04 1.67 1.65 3knkW1 ARG 15 HD2 -0.00 0.03 0.01 -0.04 3.22 3.21 3knkW1 ARG 15 HD3 -0.01 -0.02 0.01 -0.04 3.22 3.17 3knkW1 LYS 16 H 0.00 0.19 -0.48 -0.55 8.42 7.58 3knkW1 LYS 16 HA 0.02 0.06 0.35 -0.75 4.32 4.00 3knkW1 LYS 16 HB2 0.02 0.20 0.14 -0.04 1.87 2.18 3knkW1 LYS 16 HB3 0.03 -0.07 0.04 -0.04 1.79 1.75 3knkW1 LYS 16 HG2 0.01 -0.07 0.02 -0.04 1.46 1.37 3knkW1 LYS 16 HG3 0.01 -0.13 0.10 -0.04 1.46 1.40 3knkW1 LYS 16 HD2 0.02 -0.02 0.04 -0.04 1.69 1.69 3knkW1 LYS 16 HD3 0.02 0.04 0.02 -0.04 1.68 1.71 3knkW1 LYS 16 HE2 0.01 0.04 0.02 -0.04 2.99 3.01 3knkW1 LYS 16 HE3 0.01 0.00 0.01 -0.04 2.99 2.97 3knkW1 VAL 17 H 0.02 0.45 -0.11 -0.55 8.24 8.05 3knkW1 VAL 17 HA 0.05 0.20 0.85 -0.75 4.13 4.46 3knkW1 VAL 17 HB 0.05 -0.04 -0.11 -0.04 2.12 1.98 3knkW1 VAL 17 HG13 0.05 -0.01 -0.18 -0.04 0.97 0.79 3knkW1 VAL 17 HG23 0.01 0.03 -0.05 -0.04 0.95 0.89 3knkW1 ARG 18 H 0.02 0.50 0.06 -0.55 8.46 8.49 3knkW1 ARG 18 HA 0.02 -0.04 0.28 -0.75 4.34 3.85 3knkW1 ARG 18 HB2 0.01 0.09 -0.03 -0.04 1.90 1.93 3knkW1 ARG 18 HB3 0.02 0.04 -0.04 -0.04 1.80 1.78 3knkW1 ARG 18 HG2 0.03 -0.01 0.03 -0.04 1.67 1.68 3knkW1 ARG 18 HG3 0.01 0.02 0.02 -0.04 1.67 1.69 3knkW1 ARG 18 HD2 0.01 -0.02 -0.18 -0.04 3.22 2.99 3knkW1 ARG 18 HD3 0.01 0.04 -0.05 -0.04 3.22 3.18 3knkW1 LEU 19 H 0.02 0.25 -0.65 -0.55 8.37 7.44 3knkW1 LEU 19 HA 0.02 0.03 0.25 -0.75 4.35 3.89 3knkW1 LEU 19 HB2 0.02 0.13 -0.10 -0.04 1.64 1.65 3knkW1 LEU 19 HB3 0.02 -0.01 -0.03 -0.04 1.64 1.59 3knkW1 LEU 19 HG 0.01 -0.03 0.01 -0.04 1.64 1.59 3knkW1 LEU 19 HD13 0.01 0.01 -0.01 -0.04 0.93 0.90 3knkW1 LEU 19 HD23 0.02 0.01 0.03 -0.04 0.89 0.90 3knkW1 VAL 20 H 0.03 1.38 -0.51 -0.55 8.24 8.59 3knkW1 VAL 20 HA 0.03 0.13 0.72 -0.75 4.13 4.26 3knkW1 VAL 20 HB 0.04 -0.06 0.11 -0.04 2.12 2.17 3knkW1 VAL 20 HG13 0.03 -0.02 -0.18 -0.04 0.97 0.77 3knkW1 VAL 20 HG23 0.05 -0.02 -0.04 -0.04 0.95 0.90 3knkW1 VAL 21 H 0.03 0.23 -0.02 -0.55 8.24 7.93 3knkW1 VAL 21 HA 0.01 0.03 0.29 -0.75 4.13 3.71 3knkW1 VAL 21 HB 0.02 -0.00 -0.03 -0.04 2.12 2.06 3knkW1 VAL 21 HG13 0.01 -0.00 -0.00 -0.04 0.97 0.93 3knkW1 VAL 21 HG23 0.02 0.00 -0.11 -0.04 0.95 0.82 3knkW1 ASP 22 H 0.01 0.21 -1.41 -0.55 8.40 6.66 3knkW1 ASP 22 HA 0.01 0.10 0.80 -0.75 4.63 4.78 3knkW1 ASP 22 HB2 0.01 0.13 -0.14 -0.04 2.71 2.67 3knkW1 ASP 22 HB3 0.01 -0.02 0.03 -0.04 2.70 2.68 3knkW1 LEU 23 H 0.01 0.88 0.19 -0.55 8.37 8.91 3knkW1 LEU 23 HA 0.01 0.11 0.60 -0.75 4.35 4.31 3knkW1 LEU 23 HB2 0.01 0.24 0.30 -0.04 1.64 2.16 3knkW1 LEU 23 HB3 0.01 -0.08 -0.02 -0.04 1.64 1.52 3knkW1 LEU 23 HG 0.02 -0.05 0.06 -0.04 1.64 1.62 3knkW1 LEU 23 HD13 0.02 0.08 0.06 -0.04 0.93 1.05 3knkW1 LEU 23 HD23 0.02 -0.03 0.07 -0.04 0.89 0.91 3knkW1 ILE 24 H 0.00 0.12 -0.12 -0.55 8.25 7.69 3knkW1 ILE 24 HA -0.00 0.23 0.66 -0.75 4.18 4.31 3knkW1 ILE 24 HB -0.01 -0.08 0.08 -0.04 1.89 1.85 3knkW1 ILE 24 HG12 -0.00 0.03 -0.08 -0.04 1.49 1.39 3knkW1 ILE 24 HG13 -0.01 0.11 -0.44 -0.04 1.21 0.83 3knkW1 ILE 24 HG23 0.00 0.02 -0.10 -0.04 0.93 0.80 3knkW1 ILE 24 HD13 -0.01 -0.01 -0.09 -0.04 0.88 0.73 3knkW1 ARG 25 H -0.01 0.18 -0.55 -0.55 8.46 7.53 3knkW1 ARG 25 HA -0.04 -0.02 0.57 -0.75 4.34 4.10 3knkW1 ARG 25 HB2 -0.00 0.13 0.16 -0.04 1.90 2.15 3knkW1 ARG 25 HB3 -0.01 0.06 0.13 -0.04 1.80 1.93 3knkW1 ARG 25 HG2 -0.04 0.12 -0.14 -0.04 1.67 1.57 3knkW1 ARG 25 HG3 -0.01 -0.25 0.08 -0.04 1.67 1.45 3knkW1 ARG 25 HD2 -0.00 0.01 0.02 -0.04 3.22 3.21 3knkW1 ARG 25 HD3 0.01 0.03 0.05 -0.04 3.22 3.26 3knkW1 GLY 26 H -0.11 0.09 0.24 -0.55 8.43 8.11 3knkW1 GLY 26 HA2 -0.25 0.45 0.41 -0.51 4.01 4.11 3knkW1 GLY 26 HA3 -0.09 0.09 0.52 -0.51 4.01 4.02 3knkW1 LYS 27 H -0.05 0.18 -0.00 -0.55 8.42 7.99 3knkW1 LYS 27 HA 0.03 0.30 0.97 -0.75 4.32 4.87 3knkW1 LYS 27 HB2 0.02 -0.06 -0.02 -0.04 1.87 1.76 3knkW1 LYS 27 HB3 0.02 0.01 0.07 -0.04 1.79 1.85 3knkW1 LYS 27 HG2 -0.01 0.10 -0.52 -0.04 1.46 0.99 3knkW1 LYS 27 HG3 -0.01 -0.02 -0.16 -0.04 1.46 1.23 3knkW1 LYS 27 HD2 0.00 0.65 0.22 -0.04 1.69 2.53 3knkW1 LYS 27 HD3 0.01 -0.15 -0.09 -0.04 1.68 1.42 3knkW1 LYS 27 HE2 0.01 -0.02 -0.01 -0.04 2.99 2.93 3knkW1 LYS 27 HE3 0.01 -0.11 -0.03 -0.04 2.99 2.82 3knkW1 SER 28 H 0.06 0.15 0.20 -0.55 8.46 8.31 3knkW1 SER 28 HA 0.13 0.27 0.67 -0.75 4.49 4.81 3knkW1 SER 28 HB2 0.07 0.16 0.20 -0.04 3.95 4.34 3knkW1 SER 28 HB3 0.05 -0.00 0.26 -0.04 3.93 4.20 3knkW1 LEU 29 H 0.09 0.81 0.27 -0.55 8.37 9.00 3knkW1 LEU 29 HA 0.04 0.02 0.25 -0.75 4.35 3.90 3knkW1 LEU 29 HB2 0.06 0.01 -0.17 -0.04 1.64 1.50 3knkW1 LEU 29 HB3 0.04 0.10 0.06 -0.04 1.64 1.80 3knkW1 LEU 29 HG 0.02 0.00 -0.22 -0.04 1.64 1.40 3knkW1 LEU 29 HD13 0.01 -0.03 0.00 -0.04 0.93 0.88 3knkW1 LEU 29 HD23 0.03 0.03 -0.05 -0.04 0.89 0.85 3knkW1 GLU 30 H 0.04 0.13 -0.28 -0.55 8.60 7.94 3knkW1 GLU 30 HA 0.01 0.10 0.44 -0.75 4.29 4.08 3knkW1 GLU 30 HB2 0.03 0.02 0.12 -0.04 2.09 2.21 3knkW1 GLU 30 HB3 0.02 0.02 -0.05 -0.04 1.99 1.95 3knkW1 GLU 30 HG2 0.01 0.01 0.01 -0.04 2.34 2.34 3knkW1 GLU 30 HG3 0.02 0.02 0.02 -0.04 2.34 2.35 3knkW1 GLU 31 H 0.03 0.02 -0.23 -0.55 8.60 7.88 3knkW1 GLU 31 HA 0.03 0.04 0.34 -0.75 4.29 3.95 3knkW1 GLU 31 HB2 0.03 -0.08 0.19 -0.04 2.09 2.19 3knkW1 GLU 31 HB3 0.03 0.04 0.15 -0.04 1.99 2.17 3knkW1 GLU 31 HG2 0.03 0.02 0.03 -0.04 2.34 2.37 3knkW1 GLU 31 HG3 0.02 0.02 -0.13 -0.04 2.34 2.20 3knkW1 ALA 32 H 0.02 0.58 -0.13 -0.55 8.40 8.32 3knkW1 ALA 32 HA 0.01 -0.01 0.29 -0.75 4.34 3.87 3knkW1 ALA 32 HB3 0.00 0.03 -0.00 -0.04 1.41 1.40 3knkW1 ARG 33 H -0.00 0.43 -0.26 -0.55 8.46 8.08 3knkW1 ARG 33 HA -0.03 -0.02 0.28 -0.75 4.34 3.81 3knkW1 ARG 33 HB2 -0.01 0.13 0.11 -0.04 1.90 2.09 3knkW1 ARG 33 HB3 -0.03 -0.04 -0.00 -0.04 1.80 1.69 3knkW1 ARG 33 HG2 -0.02 -0.09 0.02 -0.04 1.67 1.54 3knkW1 ARG 33 HG3 -0.00 0.41 0.12 -0.04 1.67 2.15 3knkW1 ARG 33 HD2 -0.01 -0.01 -0.02 -0.04 3.22 3.15 3knkW1 ARG 33 HD3 -0.02 -0.03 -0.01 -0.04 3.22 3.12 3knkW1 ASN 34 H 0.00 0.47 -0.27 -0.55 8.53 8.18 3knkW1 ASN 34 HA -0.03 0.04 0.48 -0.75 4.76 4.50 3knkW1 ASN 34 HB2 0.04 0.11 0.20 -0.04 2.88 3.18 3knkW1 ASN 34 HB3 0.08 -0.05 -0.01 -0.04 2.79 2.77 3knkW1 ASN 34 HD21 0.02 -0.13 -0.01 -0.04 7.03 6.87 3knkW1 ASN 34 HD22 0.02 0.77 0.17 -0.04 7.74 8.66 3knkW1 ILE 35 H 0.02 0.56 0.08 -0.55 8.25 8.36 3knkW1 ILE 35 HA 0.08 0.02 0.41 -0.75 4.18 3.94 3knkW1 ILE 35 HB 0.02 0.07 0.08 -0.04 1.89 2.02 3knkW1 ILE 35 HG12 0.05 -0.02 0.02 -0.04 1.49 1.50 3knkW1 ILE 35 HG13 0.04 -0.01 0.02 -0.04 1.21 1.22 3knkW1 ILE 35 HG23 0.02 -0.00 -0.21 -0.04 0.93 0.70 3knkW1 ILE 35 HD13 0.03 -0.00 -0.05 -0.04 0.88 0.81 3knkW1 LEU 36 H -0.02 0.85 -0.02 -0.55 8.37 8.64 3knkW1 LEU 36 HA -0.01 -0.03 0.38 -0.75 4.35 3.94 3knkW1 LEU 36 HB2 -0.04 0.11 -0.08 -0.04 1.64 1.58 3knkW1 LEU 36 HB3 -0.03 -0.06 -0.08 -0.04 1.64 1.44 3knkW1 LEU 36 HG -0.01 0.12 0.05 -0.04 1.64 1.76 3knkW1 LEU 36 HD13 -0.01 0.00 -0.13 -0.04 0.93 0.75 3knkW1 LEU 36 HD23 0.00 -0.04 -0.07 -0.04 0.89 0.75 3knkW1 ARG 37 H -0.15 0.30 -0.75 -0.55 8.46 7.31 3knkW1 ARG 37 HA -0.25 -0.02 0.39 -0.75 4.34 3.70 3knkW1 ARG 37 HB2 -0.28 0.10 0.18 -0.04 1.90 1.85 3knkW1 ARG 37 HB3 -0.57 0.37 0.20 -0.04 1.80 1.76 3knkW1 ARG 37 HG2 -0.57 -0.06 0.01 -0.04 1.67 1.01 3knkW1 ARG 37 HG3 -1.83 -0.02 -0.12 -0.04 1.67 -0.34 3knkW1 ARG 37 HD2 -0.29 -0.02 0.11 -0.04 3.22 2.99 3knkW1 ARG 37 HD3 -0.21 -0.00 0.05 -0.04 3.22 3.01 3knkW1 TYR 38 H -0.07 0.43 -0.29 -0.55 8.29 7.81 3knkW1 TYR 38 HA 0.01 0.20 0.94 -0.75 4.56 4.96 3knkW1 TYR 38 HB2 0.01 0.04 0.04 -0.04 3.06 3.10 3knkW1 TYR 38 HB3 0.01 -0.08 0.12 -0.04 2.98 2.99 3knkW1 TYR 38 HD2 0.01 0.02 -0.02 -0.04 7.15 7.11 3knkW1 TYR 38 HE2 0.00 -0.04 -0.03 -0.04 6.85 6.74 3knkW1 THR 39 H 0.03 0.28 -0.05 -0.55 8.28 7.99 3knkW1 THR 39 HA 0.06 0.03 0.46 -0.75 4.39 4.19 3knkW1 THR 39 HB 0.03 -0.05 0.17 -0.04 4.32 4.42 3knkW1 THR 39 HG23 0.03 -0.00 -0.09 -0.04 1.22 1.12 3knkW1 ASN 40 H 0.05 0.25 0.25 -0.55 8.53 8.54 3knkW1 ASN 40 HA 0.04 0.01 0.32 -0.75 4.76 4.38 3knkW1 ASN 40 HB2 0.04 0.09 0.15 -0.04 2.88 3.13 3knkW1 ASN 40 HB3 0.03 -0.02 0.23 -0.04 2.79 2.99 3knkW1 ASN 40 HD21 0.02 -0.03 -0.01 -0.04 7.03 6.97 3knkW1 ASN 40 HD22 0.02 0.01 0.05 -0.04 7.74 7.78 3knkW1 LYS 41 H 0.03 0.30 0.21 -0.55 8.42 8.40 3knkW1 LYS 41 HA 0.03 0.04 0.51 -0.75 4.32 4.14 3knkW1 LYS 41 HB2 0.04 0.06 -0.11 -0.04 1.87 1.81 3knkW1 LYS 41 HB3 0.05 -0.13 -0.05 -0.04 1.79 1.62 3knkW1 LYS 41 HG2 0.03 0.37 -0.28 -0.04 1.46 1.54 3knkW1 LYS 41 HG3 0.03 -0.02 -0.11 -0.04 1.46 1.32 3knkW1 LYS 41 HD2 0.03 -0.11 0.08 -0.04 1.69 1.66 3knkW1 LYS 41 HD3 0.03 0.04 0.19 -0.04 1.68 1.90 3knkW1 LYS 41 HE2 0.02 0.04 0.03 -0.04 2.99 3.05 3knkW1 LYS 41 HE3 0.02 0.01 0.01 -0.04 2.99 2.99 3knkW1 ARG 42 H 0.04 0.19 0.10 -0.55 8.46 8.24 3knkW1 ARG 42 HA -0.00 0.08 0.34 -0.75 4.34 4.00 3knkW1 ARG 42 HB2 0.04 0.05 0.15 -0.04 1.90 2.10 3knkW1 ARG 42 HB3 0.09 -0.06 0.12 -0.04 1.80 1.91 3knkW1 ARG 42 HG2 0.30 -0.02 -0.23 -0.04 1.67 1.68 3knkW1 ARG 42 HG3 -0.00 0.02 -0.00 -0.04 1.67 1.64 3knkW1 ARG 42 HD2 0.04 0.02 0.02 -0.04 3.22 3.26 3knkW1 ARG 42 HD3 0.10 -0.03 0.02 -0.04 3.22 3.26 3knkW1 GLY 43 H 0.13 0.09 -0.27 -0.55 8.43 7.84 3knkW1 GLY 43 HA2 0.54 0.00 0.22 -0.51 4.01 4.26 3knkW1 GLY 43 HA3 0.19 0.02 0.18 -0.51 4.01 3.89 3knkW1 ALA 44 H 0.08 0.53 -0.20 -0.55 8.40 8.26 3knkW1 ALA 44 HA 0.05 -0.04 0.31 -0.75 4.34 3.91 3knkW1 ALA 44 HB3 0.03 0.06 0.13 -0.04 1.41 1.58 3knkW1 TYR 45 H 0.08 0.28 -0.07 -0.55 8.29 8.03 3knkW1 TYR 45 HA -0.11 0.03 0.32 -0.75 4.56 4.05 3knkW1 TYR 45 HB2 -0.19 0.01 0.10 -0.04 3.06 2.94 3knkW1 TYR 45 HB3 -0.40 0.16 0.10 -0.04 2.98 2.80 3knkW1 TYR 45 HD2 -0.80 0.00 -0.12 -0.04 7.15 6.19 3knkW1 TYR 45 HE2 -0.20 0.01 -0.04 -0.04 6.85 6.59 3knkW1 PHE 46 H 0.12 0.24 -0.38 -0.55 8.34 7.76 3knkW1 PHE 46 HA -0.06 0.00 0.49 -0.75 4.62 4.29 3knkW1 PHE 46 HB2 0.07 0.16 0.06 -0.04 3.15 3.41 3knkW1 PHE 46 HB3 0.05 -0.08 -0.01 -0.04 3.06 2.97 3knkW1 PHE 46 HD2 0.13 -0.06 -0.06 -0.04 7.28 7.25 3knkW1 PHE 46 HE2 0.11 -0.00 -0.09 -0.04 7.38 7.35 3knkW1 PHE 46 HZ 0.03 0.05 -0.06 -0.04 7.32 7.30 3knkW1 VAL 47 H 0.11 0.72 -0.07 -0.55 8.24 8.45 3knkW1 VAL 47 HA 0.04 -0.03 0.52 -0.75 4.13 3.90 3knkW1 VAL 47 HB 0.03 0.07 0.05 -0.04 2.12 2.23 3knkW1 VAL 47 HG13 0.01 -0.04 0.00 -0.04 0.97 0.90 3knkW1 VAL 47 HG23 0.08 0.07 -0.21 -0.04 0.95 0.85 3knkW1 ALA 48 H -0.10 0.33 -0.80 -0.55 8.40 7.29 3knkW1 ALA 48 HA -0.07 0.11 0.71 -0.75 4.34 4.34 3knkW1 ALA 48 HB3 -0.17 0.01 0.07 -0.04 1.41 1.28 3knkW1 LYS 49 H -0.23 0.35 0.10 -0.55 8.42 8.08 3knkW1 LYS 49 HA -0.11 0.03 0.27 -0.75 4.32 3.75 3knkW1 LYS 49 HB2 -0.05 -0.01 0.17 -0.04 1.87 1.94 3knkW1 LYS 49 HB3 -0.07 0.03 0.05 -0.04 1.79 1.76 3knkW1 LYS 49 HG2 -0.45 0.18 0.20 -0.04 1.46 1.35 3knkW1 LYS 49 HG3 -0.23 0.01 0.07 -0.04 1.46 1.27 3knkW1 LYS 49 HD2 -0.17 0.01 0.05 -0.04 1.69 1.53 3knkW1 LYS 49 HD3 -0.27 -0.10 0.09 -0.04 1.68 1.36 3knkW1 LYS 49 HE2 -0.33 -0.02 0.02 -0.04 2.99 2.63 3knkW1 LYS 49 HE3 -1.35 0.06 0.02 -0.04 2.99 1.68 3knkW1 VAL 50 H -0.02 0.32 -0.18 -0.55 8.24 7.81 3knkW1 VAL 50 HA -0.02 0.05 0.23 -0.75 4.13 3.63 3knkW1 VAL 50 HB -0.01 0.02 -0.04 -0.04 2.12 2.05 3knkW1 VAL 50 HG13 -0.00 -0.00 -0.10 -0.04 0.97 0.83 3knkW1 VAL 50 HG23 -0.04 -0.01 -0.34 -0.04 0.95 0.52 3knkW1 LEU 51 H -0.03 0.16 -0.35 -0.55 8.37 7.61 3knkW1 LEU 51 HA -0.02 -0.02 0.32 -0.75 4.35 3.87 3knkW1 LEU 51 HB2 -0.02 0.02 0.05 -0.04 1.64 1.65 3knkW1 LEU 51 HB3 -0.03 0.13 0.15 -0.04 1.64 1.85 3knkW1 LEU 51 HG -0.02 0.03 -0.04 -0.04 1.64 1.57 3knkW1 LEU 51 HD13 -0.01 -0.03 -0.31 -0.04 0.93 0.53 3knkW1 LEU 51 HD23 -0.01 -0.02 -0.07 -0.04 0.89 0.75 3knkW1 GLU 52 H -0.04 0.56 -0.08 -0.55 8.60 8.49 3knkW1 GLU 52 HA -0.02 -0.07 0.31 -0.75 4.29 3.75 3knkW1 GLU 52 HB2 -0.06 0.01 -0.15 -0.04 2.09 1.85 3knkW1 GLU 52 HB3 -0.05 0.08 -0.14 -0.04 1.99 1.84 3knkW1 GLU 52 HG2 -0.04 0.00 -0.05 -0.04 2.34 2.20 3knkW1 GLU 52 HG3 -0.03 -0.04 0.01 -0.04 2.34 2.25 3knkW1 SER 53 H -0.03 0.72 -0.51 -0.55 8.46 8.10 3knkW1 SER 53 HA -0.02 -0.02 0.51 -0.75 4.49 4.21 3knkW1 SER 53 HB2 -0.02 -0.10 0.02 -0.04 3.95 3.81 3knkW1 SER 53 HB3 -0.02 0.12 0.09 -0.04 3.93 4.07 3knkW1 ALA 54 H -0.01 0.52 0.01 -0.55 8.40 8.37 3knkW1 ALA 54 HA 0.01 0.07 0.38 -0.75 4.34 4.04 3knkW1 ALA 54 HB3 -0.01 -0.04 0.05 -0.04 1.41 1.38 3knkW1 ALA 55 H 0.00 0.60 -0.12 -0.55 8.40 8.34 3knkW1 ALA 55 HA 0.03 0.00 0.33 -0.75 4.34 3.95 3knkW1 ALA 55 HB3 0.01 0.02 0.05 -0.04 1.41 1.45 3knkW1 ALA 56 H -0.00 0.46 -0.06 -0.55 8.40 8.25 3knkW1 ALA 56 HA 0.00 -0.18 0.38 -0.75 4.34 3.79 3knkW1 ALA 56 HB3 -0.01 0.03 0.18 -0.04 1.41 1.57 3knkW1 ASN 57 H 0.03 0.80 0.39 -0.55 8.53 9.21 3knkW1 ASN 57 HA -0.04 0.04 0.64 -0.75 4.76 4.65 3knkW1 ASN 57 HB2 0.04 0.38 -0.13 -0.04 2.88 3.13 3knkW1 ASN 57 HB3 0.13 -0.06 -0.03 -0.04 2.79 2.79 3knkW1 ASN 57 HD21 0.01 -0.16 0.06 -0.04 7.03 6.90 3knkW1 ASN 57 HD22 0.03 0.15 0.10 -0.04 7.74 7.99 3knkW1 ALA 58 H 0.07 0.73 0.36 -0.55 8.40 9.02 3knkW1 ALA 58 HA 0.18 0.11 0.30 -0.75 4.34 4.18 3knkW1 ALA 58 HB3 0.06 0.02 0.02 -0.04 1.41 1.46 3knkW1 VAL 59 H 0.03 0.15 -0.18 -0.55 8.24 7.69 3knkW1 VAL 59 HA 0.02 -0.11 0.63 -0.75 4.13 3.92 3knkW1 VAL 59 HB 0.01 0.00 0.08 -0.04 2.12 2.16 3knkW1 VAL 59 HG13 -0.00 0.04 -0.12 -0.04 0.97 0.85 3knkW1 VAL 59 HG23 0.01 -0.00 -0.07 -0.04 0.95 0.85 3knkW1 ASN 60 H -0.01 0.08 -0.13 -0.55 8.53 7.92 3knkW1 ASN 60 HA -0.03 0.04 0.27 -0.75 4.76 4.30 3knkW1 ASN 60 HB2 -0.04 0.13 -0.02 -0.04 2.88 2.90 3knkW1 ASN 60 HB3 -0.04 0.05 -0.04 -0.04 2.79 2.72 3knkW1 ASN 60 HD21 -0.02 -0.03 0.03 -0.04 7.03 6.97 3knkW1 ASN 60 HD22 -0.02 0.05 0.02 -0.04 7.74 7.74 3knkW1 ASN 61 H -0.13 0.22 -0.22 -0.55 8.53 7.86 3knkW1 ASN 61 HA -0.12 0.21 0.98 -0.75 4.76 5.08 3knkW1 ASN 61 HB2 -0.46 0.06 0.04 -0.04 2.88 2.48 3knkW1 ASN 61 HB3 -0.31 -0.01 0.09 -0.04 2.79 2.52 3knkW1 ASN 61 HD21 -0.07 -0.03 -0.05 -0.04 7.03 6.84 3knkW1 ASN 61 HD22 -0.09 0.05 0.01 -0.04 7.74 7.68 3knkW1 HIS 62 H -0.06 0.09 -0.29 -0.55 8.41 7.61 3knkW1 HIS 62 HA 0.00 0.17 0.90 -0.75 4.63 4.95 3knkW1 HIS 62 HB2 0.00 0.07 0.04 -0.04 3.26 3.33 3knkW1 HIS 62 HB3 0.00 -0.04 0.06 -0.04 3.20 3.19 3knkW1 HIS 62 HD2 0.00 0.05 -0.04 -0.04 6.97 6.94 3knkW1 HIS 62 HE1 0.00 -0.04 -0.03 -0.04 7.75 7.63 3knkW1 ASP 63 H 0.02 0.38 0.01 -0.55 8.40 8.26 3knkW1 ASP 63 HA 0.02 -0.19 0.52 -0.75 4.63 4.23 3knkW1 ASP 63 HB2 0.01 -0.08 0.11 -0.04 2.71 2.71 3knkW1 ASP 63 HB3 0.01 -0.02 0.08 -0.04 2.70 2.73 3knkW1 MET 64 H 0.03 -0.14 -0.15 -0.55 8.47 7.66 3knkW1 MET 64 HA 0.02 0.25 0.91 -0.75 4.52 4.94 3knkW1 MET 64 HB2 0.05 -0.17 -0.16 -0.04 2.15 1.83 3knkW1 MET 64 HB3 0.02 -0.03 0.05 -0.04 2.03 2.03 3knkW1 MET 64 HG2 0.02 -0.02 -0.01 -0.04 2.63 2.58 3knkW1 MET 64 HG3 0.08 0.52 -0.55 -0.04 2.56 2.56 3knkW1 MET 64 HE3 -0.01 -0.01 -0.23 -0.04 2.10 1.81 3knkW1 LEU 65 H 0.01 -0.02 -0.04 -0.55 8.37 7.77 3knkW1 LEU 65 HA 0.00 -0.06 0.37 -0.75 4.35 3.90 3knkW1 LEU 65 HB2 -0.01 0.07 -0.54 -0.04 1.64 1.13 3knkW1 LEU 65 HB3 -0.01 0.16 0.38 -0.04 1.64 2.12 3knkW1 LEU 65 HG -0.01 0.05 -0.01 -0.04 1.64 1.62 3knkW1 LEU 65 HD13 -0.03 0.02 0.01 -0.04 0.93 0.89 3knkW1 LEU 65 HD23 -0.01 -0.17 -0.05 -0.04 0.89 0.61 3knkW1 GLU 66 H 0.00 0.12 0.06 -0.55 8.60 8.24 3knkW1 GLU 66 HA 0.01 0.07 0.14 -0.75 4.29 3.76 3knkW1 GLU 66 HB2 0.01 -0.03 0.09 -0.04 2.09 2.11 3knkW1 GLU 66 HB3 0.00 0.01 0.01 -0.04 1.99 1.98 3knkW1 GLU 66 HG2 0.01 0.02 -0.08 -0.04 2.34 2.25 3knkW1 GLU 66 HG3 0.01 0.01 0.05 -0.04 2.34 2.37 3knkW1 ASP 67 H -0.00 -0.05 -0.60 -0.55 8.40 7.19 3knkW1 ASP 67 HA 0.01 0.14 0.68 -0.75 4.63 4.71 3knkW1 ASP 67 HB2 -0.00 -0.05 0.05 -0.04 2.71 2.66 3knkW1 ASP 67 HB3 -0.01 0.04 -0.04 -0.04 2.70 2.64 3knkW1 ARG 68 H -0.02 0.12 0.02 -0.55 8.46 8.03 3knkW1 ARG 68 HA -0.03 0.03 0.48 -0.75 4.34 4.07 3knkW1 ARG 68 HB2 -0.04 0.21 0.25 -0.04 1.90 2.27 3knkW1 ARG 68 HB3 -0.08 -0.19 0.27 -0.04 1.80 1.75 3knkW1 ARG 68 HG2 -0.04 -0.07 0.08 -0.04 1.67 1.60 3knkW1 ARG 68 HG3 -0.07 0.05 0.08 -0.04 1.67 1.69 3knkW1 ARG 68 HD2 -0.17 -0.12 0.08 -0.04 3.22 2.97 3knkW1 ARG 68 HD3 -0.06 0.05 -0.00 -0.04 3.22 3.16 3knkW1 LEU 69 H 0.02 0.73 -0.31 -0.55 8.37 8.27 3knkW1 LEU 69 HA 0.04 0.39 1.06 -0.75 4.35 5.09 3knkW1 LEU 69 HB2 0.04 0.06 -0.02 -0.04 1.64 1.68 3knkW1 LEU 69 HB3 0.07 -0.06 -0.06 -0.04 1.64 1.55 3knkW1 LEU 69 HG 0.02 0.12 -0.53 -0.04 1.64 1.21 3knkW1 LEU 69 HD13 0.04 -0.04 -0.14 -0.04 0.93 0.74 3knkW1 LEU 69 HD23 0.04 0.08 -0.24 -0.04 0.89 0.73 3knkW1 TYR 70 H 0.33 0.62 0.31 -0.55 8.29 9.00 3knkW1 TYR 70 HA 0.01 -0.13 0.82 -0.75 4.56 4.51 3knkW1 TYR 70 HB2 0.02 0.02 -0.20 -0.04 3.06 2.86 3knkW1 TYR 70 HB3 0.03 -0.05 -0.29 -0.04 2.98 2.63 3knkW1 TYR 70 HD2 0.02 -0.04 -0.04 -0.04 7.15 7.05 3knkW1 TYR 70 HE2 0.01 -0.16 -0.09 -0.04 6.85 6.58 3knkW1 VAL 71 H -0.07 0.68 0.18 -0.55 8.24 8.48 3knkW1 VAL 71 HA -0.08 0.04 0.64 -0.75 4.13 3.98 3knkW1 VAL 71 HB -0.13 -0.60 0.42 -0.04 2.12 1.77 3knkW1 VAL 71 HG13 -0.05 0.04 -0.06 -0.04 0.97 0.85 3knkW1 VAL 71 HG23 -0.03 0.23 0.11 -0.04 0.95 1.22 3knkW1 LYS 72 H -0.12 0.26 0.40 -0.55 8.42 8.40 3knkW1 LYS 72 HA -0.48 0.09 0.46 -0.75 4.32 3.63 3knkW1 LYS 72 HB2 0.12 -0.13 0.14 -0.04 1.87 1.96 3knkW1 LYS 72 HB3 0.00 0.61 0.20 -0.04 1.79 2.56 3knkW1 LYS 72 HG2 0.05 -0.01 -0.10 -0.04 1.46 1.36 3knkW1 LYS 72 HG3 0.01 -0.01 -0.26 -0.04 1.46 1.15 3knkW1 LYS 72 HD2 0.06 0.01 0.07 -0.04 1.69 1.79 3knkW1 LYS 72 HD3 0.19 -0.01 0.00 -0.04 1.68 1.82 3knkW1 LYS 72 HE2 0.04 -0.02 0.00 -0.04 2.99 2.96 3knkW1 LYS 72 HE3 0.08 -0.01 -0.01 -0.04 2.99 3.01 3knkW1 ALA 73 H -0.06 0.12 -0.02 -0.55 8.40 7.90 3knkW1 ALA 73 HA -0.01 0.02 0.39 -0.75 4.34 3.99 3knkW1 ALA 73 HB3 0.05 0.08 0.04 -0.04 1.41 1.54 3knkW1 ALA 74 H 0.04 0.18 0.18 -0.55 8.40 8.25 3knkW1 ALA 74 HA -0.06 0.31 1.13 -0.75 4.34 4.96 3knkW1 ALA 74 HB3 -0.02 -0.02 0.10 -0.04 1.41 1.43 3knkW1 TYR 75 H -0.11 0.42 0.26 -0.55 8.29 8.31 3knkW1 TYR 75 HA -0.00 -0.02 0.38 -0.75 4.56 4.17 3knkW1 TYR 75 HB2 0.00 -0.03 0.05 -0.04 3.06 3.04 3knkW1 TYR 75 HB3 -0.00 0.38 0.32 -0.04 2.98 3.63 3knkW1 TYR 75 HD2 0.01 0.03 -0.42 -0.04 7.15 6.73 3knkW1 TYR 75 HE2 0.02 0.00 -0.13 -0.04 6.85 6.69 3knkW1 VAL 76 H 0.11 0.21 0.17 -0.55 8.24 8.18 3knkW1 VAL 76 HA 0.05 0.25 1.16 -0.75 4.13 4.83 3knkW1 VAL 76 HB 0.02 -0.05 0.01 -0.04 2.12 2.06 3knkW1 VAL 76 HG13 0.03 -0.03 0.07 -0.04 0.97 1.01 3knkW1 VAL 76 HG23 0.01 0.01 -0.17 -0.04 0.95 0.76 3knkW1 ASP 77 H 0.09 0.55 0.36 -0.55 8.40 8.86 3knkW1 ASP 77 HA 0.03 0.15 0.89 -0.75 4.63 4.94 3knkW1 ASP 77 HB2 0.10 -0.02 0.09 -0.04 2.71 2.83 3knkW1 ASP 77 HB3 0.01 0.05 0.13 -0.04 2.70 2.86 3knkW1 GLU 78 H -0.06 0.14 0.22 -0.55 8.60 8.36 3knkW1 GLU 78 HA -0.12 0.18 0.87 -0.75 4.29 4.47 3knkW1 GLU 78 HB2 -0.06 -0.05 0.17 -0.04 2.09 2.11 3knkW1 GLU 78 HB3 -0.08 0.01 0.16 -0.04 1.99 2.04 3knkW1 GLU 78 HG2 -0.10 0.06 -0.07 -0.04 2.34 2.19 3knkW1 GLU 78 HG3 -0.09 0.03 0.24 -0.04 2.34 2.48 3knkW1 GLY 79 H -0.21 0.44 0.22 -0.55 8.43 8.33 3knkW1 GLY 79 HA2 -0.43 0.27 0.94 -0.51 4.01 4.27 3knkW1 GLY 79 HA3 -0.54 -0.04 0.14 -0.51 4.01 3.05 3knkW1 PRO 80 HA -0.10 -0.01 0.38 -0.51 4.44 4.20 3knkW1 PRO 80 HB2 -0.13 0.10 0.11 -0.04 2.28 2.31 3knkW1 PRO 80 HB3 -0.11 0.03 0.13 -0.04 2.02 2.03 3knkW1 PRO 80 HG2 -0.48 -0.00 0.03 -0.04 2.03 1.54 3knkW1 PRO 80 HG3 -0.41 0.07 0.08 -0.04 2.03 1.72 3knkW1 PRO 80 HD2 -0.36 0.03 0.19 -0.04 3.68 3.50 3knkW1 PRO 80 HD3 -0.17 0.17 0.19 -0.04 3.65 3.79 3knkW1 ALA 81 H -0.08 0.01 0.21 -0.55 8.40 7.99 3knkW1 ALA 81 HA -0.06 0.11 0.52 -0.75 4.34 4.15 3knkW1 ALA 81 HB3 -0.04 -0.02 -0.01 -0.04 1.41 1.29 3knkW1 LEU 82 H -0.03 0.73 0.24 -0.55 8.37 8.77 3knkW1 LEU 82 HA -0.01 0.15 0.87 -0.75 4.35 4.60 3knkW1 LEU 82 HB2 -0.01 -0.07 0.21 -0.04 1.64 1.73 3knkW1 LEU 82 HB3 -0.00 0.03 0.04 -0.04 1.64 1.66 3knkW1 LEU 82 HG -0.02 0.01 -0.08 -0.04 1.64 1.51 3knkW1 LEU 82 HD13 0.01 -0.01 -0.03 -0.04 0.93 0.86 3knkW1 LEU 82 HD23 -0.01 0.07 -0.19 -0.04 0.89 0.72 3knkW1 LYS 83 H -0.01 0.18 0.04 -0.55 8.42 8.08 3knkW1 LYS 83 HA -0.01 0.03 0.71 -0.75 4.32 4.29 3knkW1 LYS 83 HB2 -0.01 -0.01 0.02 -0.04 1.87 1.83 3knkW1 LYS 83 HB3 -0.01 0.09 -0.05 -0.04 1.79 1.78 3knkW1 LYS 83 HG2 -0.01 -0.03 -0.11 -0.04 1.46 1.26 3knkW1 LYS 83 HG3 -0.01 -0.02 -0.01 -0.04 1.46 1.38 3knkW1 LYS 83 HD2 -0.01 0.00 -0.02 -0.04 1.69 1.63 3knkW1 LYS 83 HD3 -0.01 0.03 -0.05 -0.04 1.68 1.61 3knkW1 LYS 83 HE2 -0.01 0.02 -0.03 -0.04 2.99 2.92 3knkW1 LYS 83 HE3 -0.01 0.00 -0.02 -0.04 2.99 2.92 3knkW1 ARG 84 H -0.01 1.06 0.48 -0.55 8.46 9.44 3knkW1 ARG 84 HA -0.00 0.13 0.92 -0.75 4.34 4.63 3knkW1 ARG 84 HB2 -0.00 -0.07 0.02 -0.04 1.90 1.81 3knkW1 ARG 84 HB3 -0.00 0.07 0.17 -0.04 1.80 2.00 3knkW1 ARG 84 HG2 -0.00 0.00 -0.15 -0.04 1.67 1.48 3knkW1 ARG 84 HG3 -0.00 -0.05 -0.03 -0.04 1.67 1.55 3knkW1 ARG 84 HD2 0.00 -0.02 0.01 -0.04 3.22 3.17 3knkW1 ARG 84 HD3 0.00 0.03 0.02 -0.04 3.22 3.23 3knkW1 VAL 85 H -0.00 0.08 0.20 -0.55 8.24 7.98 3knkW1 VAL 85 HA -0.00 0.24 0.77 -0.75 4.13 4.38 3knkW1 VAL 85 HB -0.00 -0.02 0.09 -0.04 2.12 2.16 3knkW1 VAL 85 HG13 0.00 -0.03 -0.17 -0.04 0.97 0.74 3knkW1 VAL 85 HG23 -0.00 -0.00 0.01 -0.04 0.95 0.92 3knkW1 LEU 86 H -0.00 0.34 0.03 -0.55 8.37 8.20 3knkW1 LEU 86 HA -0.00 0.10 0.52 -0.75 4.35 4.21 3knkW1 LEU 86 HB2 -0.00 0.14 0.01 -0.04 1.64 1.75 3knkW1 LEU 86 HB3 -0.00 -0.10 -0.38 -0.04 1.64 1.11 3knkW1 LEU 86 HG -0.00 -0.11 -0.16 -0.04 1.64 1.34 3knkW1 LEU 86 HD13 -0.00 0.05 -0.06 -0.04 0.93 0.87 3knkW1 LEU 86 HD23 -0.00 -0.02 -0.08 -0.04 0.89 0.75 3knkW1 PRO 87 HA -0.00 -0.05 0.59 -0.51 4.44 4.46 3knkW1 PRO 87 HB2 0.00 0.08 0.01 -0.04 2.28 2.32 3knkW1 PRO 87 HB3 0.00 0.04 0.10 -0.04 2.02 2.11 3knkW1 PRO 87 HG2 0.00 0.04 0.08 -0.04 2.03 2.11 3knkW1 PRO 87 HG3 0.00 0.06 0.06 -0.04 2.03 2.11 3knkW1 PRO 87 HD2 0.00 0.13 0.20 -0.04 3.68 3.97 3knkW1 PRO 87 HD3 0.00 0.15 0.13 -0.04 3.65 3.89 3knkW1 ARG 88 H -0.00 0.02 0.24 -0.55 8.46 8.16 3knkW1 ARG 88 HA -0.00 0.23 0.79 -0.75 4.34 4.61 3knkW1 ARG 88 HB2 -0.00 0.01 0.07 -0.04 1.90 1.94 3knkW1 ARG 88 HB3 -0.00 -0.02 0.19 -0.04 1.80 1.93 3knkW1 ARG 88 HG2 -0.00 -0.13 -0.18 -0.04 1.67 1.32 3knkW1 ARG 88 HG3 -0.00 0.05 -0.04 -0.04 1.67 1.64 3knkW1 ARG 88 HD2 -0.00 0.43 -0.06 -0.04 3.22 3.54 3knkW1 ARG 88 HD3 -0.00 -0.01 -0.16 -0.04 3.22 3.00 3knkW1 ALA 89 H -0.00 0.14 0.14 -0.55 8.40 8.13 3knkW1 ALA 89 HA -0.00 0.07 0.52 -0.75 4.34 4.17 3knkW1 ALA 89 HB3 -0.00 0.02 0.10 -0.04 1.41 1.49 3knkW1 ARG 90 H -0.00 0.10 0.16 -0.55 8.46 8.17 3knkW1 ARG 90 HA -0.00 0.01 0.38 -0.75 4.34 3.97 3knkW1 ARG 90 HB2 -0.00 0.17 -0.00 -0.04 1.90 2.03 3knkW1 ARG 90 HB3 -0.00 0.05 0.10 -0.04 1.80 1.91 3knkW1 ARG 90 HG2 -0.00 -0.06 -0.01 -0.04 1.67 1.56 3knkW1 ARG 90 HG3 -0.00 0.01 -0.13 -0.04 1.67 1.51 3knkW1 ARG 90 HD2 -0.00 0.04 -0.01 -0.04 3.22 3.21 3knkW1 ARG 90 HD3 -0.00 0.00 0.01 -0.04 3.22 3.19 3knkW1 GLY 91 H -0.00 0.06 0.04 -0.55 8.43 7.98 3knkW1 GLY 91 HA2 -0.00 -0.02 0.24 -0.51 4.01 3.72 3knkW1 GLY 91 HA3 -0.00 0.03 0.33 -0.51 4.01 3.87 3knkW1 ARG 92 H -0.00 0.02 -0.68 -0.55 8.46 7.25 3knkW1 ARG 92 HA -0.00 0.19 0.50 -0.75 4.34 4.27 3knkW1 ARG 92 HB2 -0.00 0.33 -0.09 -0.04 1.90 2.09 3knkW1 ARG 92 HB3 -0.00 -0.35 0.10 -0.04 1.80 1.51 3knkW1 ARG 92 HG2 -0.00 0.01 -0.13 -0.04 1.67 1.51 3knkW1 ARG 92 HG3 -0.00 0.08 -0.01 -0.04 1.67 1.70 3knkW1 ARG 92 HD2 -0.00 0.05 0.01 -0.04 3.22 3.24 3knkW1 ARG 92 HD3 -0.00 -0.10 -0.03 -0.04 3.22 3.05 3knkW1 ALA 93 H -0.00 -0.18 0.12 -0.55 8.40 7.80 3knkW1 ALA 93 HA -0.00 0.02 0.39 -0.75 4.34 3.99 3knkW1 ALA 93 HB3 -0.00 0.09 0.06 -0.04 1.41 1.52 3knkW1 ASP 94 H -0.00 0.48 0.28 -0.55 8.40 8.61 3knkW1 ASP 94 HA -0.00 0.13 0.52 -0.75 4.63 4.52 3knkW1 ASP 94 HB2 -0.00 0.03 0.00 -0.04 2.71 2.70 3knkW1 ASP 94 HB3 -0.00 -0.03 -0.02 -0.04 2.70 2.61 3knkW1 ILE 95 H -0.00 0.16 0.05 -0.55 8.25 7.91 3knkW1 ILE 95 HA -0.00 0.28 1.04 -0.75 4.18 4.75 3knkW1 ILE 95 HB -0.00 0.07 0.02 -0.04 1.89 1.93 3knkW1 ILE 95 HG12 -0.00 -0.04 0.12 -0.04 1.49 1.52 3knkW1 ILE 95 HG13 -0.01 -0.03 0.20 -0.04 1.21 1.34 3knkW1 ILE 95 HG23 -0.00 0.00 -0.11 -0.04 0.93 0.77 3knkW1 ILE 95 HD13 -0.01 -0.01 -0.01 -0.04 0.88 0.81 3knkW1 ILE 96 H -0.00 0.24 -0.18 -0.55 8.25 7.76 3knkW1 ILE 96 HA -0.01 0.04 0.54 -0.75 4.18 4.00 3knkW1 ILE 96 HB -0.00 -0.01 -0.05 -0.04 1.89 1.79 3knkW1 ILE 96 HG12 -0.00 0.01 -0.15 -0.04 1.49 1.31 3knkW1 ILE 96 HG13 -0.01 0.03 -0.25 -0.04 1.21 0.94 3knkW1 ILE 96 HG23 -0.00 -0.04 -0.26 -0.04 0.93 0.59 3knkW1 ILE 96 HD13 -0.00 -0.00 -0.02 -0.04 0.88 0.82 3knkW1 LYS 97 H -0.01 0.16 0.14 -0.55 8.42 8.15 3knkW1 LYS 97 HA -0.01 0.22 1.39 -0.75 4.32 5.16 3knkW1 LYS 97 HB2 -0.01 -0.02 0.02 -0.04 1.87 1.81 3knkW1 LYS 97 HB3 -0.02 -0.03 -0.27 -0.04 1.79 1.43 3knkW1 LYS 97 HG2 -0.01 -0.03 -0.11 -0.04 1.46 1.26 3knkW1 LYS 97 HG3 -0.01 0.11 -0.33 -0.04 1.46 1.19 3knkW1 LYS 97 HD2 -0.02 -0.04 -0.22 -0.04 1.69 1.37 3knkW1 LYS 97 HD3 -0.02 0.03 -0.12 -0.04 1.68 1.53 3knkW1 LYS 97 HE2 -0.02 0.05 -0.06 -0.04 2.99 2.92 3knkW1 LYS 97 HE3 -0.02 -0.05 -0.08 -0.04 2.99 2.80 3knkW1 LYS 98 H -0.01 0.77 0.29 -0.55 8.42 8.91 3knkW1 LYS 98 HA -0.01 0.02 0.53 -0.75 4.32 4.10 3knkW1 LYS 98 HB2 -0.01 -0.06 0.32 -0.04 1.87 2.08 3knkW1 LYS 98 HB3 -0.01 0.03 0.07 -0.04 1.79 1.83 3knkW1 LYS 98 HG2 -0.01 0.08 0.11 -0.04 1.46 1.60 3knkW1 LYS 98 HG3 -0.00 -0.01 0.04 -0.04 1.46 1.45 3knkW1 LYS 98 HD2 -0.00 0.00 0.00 -0.04 1.69 1.65 3knkW1 LYS 98 HD3 -0.00 -0.05 -0.10 -0.04 1.68 1.48 3knkW1 LYS 98 HE2 0.00 0.02 -0.00 -0.04 2.99 2.97 3knkW1 LYS 98 HE3 0.00 -0.02 -0.02 -0.04 2.99 2.91 3knkW1 ARG 99 H -0.02 0.14 0.22 -0.55 8.46 8.25 3knkW1 ARG 99 HA -0.05 0.09 0.65 -0.75 4.34 4.28 3knkW1 ARG 99 HB2 -0.03 -0.09 0.11 -0.04 1.90 1.84 3knkW1 ARG 99 HB3 -0.05 0.00 0.19 -0.04 1.80 1.90 3knkW1 ARG 99 HG2 -0.04 0.02 0.00 -0.04 1.67 1.61 3knkW1 ARG 99 HG3 -0.02 0.15 0.04 -0.04 1.67 1.79 3knkW1 ARG 99 HD2 -0.02 -0.07 0.06 -0.04 3.22 3.14 3knkW1 ARG 99 HD3 -0.03 -0.02 0.06 -0.04 3.22 3.19 3knkW1 THR 100 H -0.08 0.24 0.27 -0.55 8.28 8.17 3knkW1 THR 100 HA -0.07 0.36 0.99 -0.75 4.39 4.92 3knkW1 THR 100 HB -0.05 0.17 -0.14 -0.04 4.32 4.25 3knkW1 THR 100 HG23 -0.13 0.03 -0.31 -0.04 1.22 0.77 3knkW1 SER 101 H -0.07 -0.11 0.31 -0.55 8.46 8.04 3knkW1 SER 101 HA -0.12 0.27 1.08 -0.75 4.49 4.96 3knkW1 SER 101 HB2 -0.07 -0.07 -0.12 -0.04 3.95 3.65 3knkW1 SER 101 HB3 -0.02 0.11 -0.05 -0.04 3.93 3.93 3knkW1 HIS 102 H 0.03 0.69 0.29 -0.55 8.41 8.86 3knkW1 HIS 102 HA 0.02 0.09 0.90 -0.75 4.63 4.90 3knkW1 HIS 102 HB2 0.02 -0.05 0.15 -0.04 3.26 3.35 3knkW1 HIS 102 HB3 0.04 0.06 0.00 -0.04 3.20 3.26 3knkW1 HIS 102 HD2 0.04 0.04 -0.03 -0.04 6.97 6.97 3knkW1 HIS 102 HE1 -0.47 0.05 0.00 -0.04 7.75 7.29 3knkW1 ILE 103 H 0.04 1.25 0.34 -0.55 8.25 9.33 3knkW1 ILE 103 HA -0.02 0.16 1.20 -0.75 4.18 4.76 3knkW1 ILE 103 HB -0.01 -0.00 0.13 -0.04 1.89 1.97 3knkW1 ILE 103 HG12 -0.00 -0.03 -0.21 -0.04 1.49 1.21 3knkW1 ILE 103 HG13 0.00 -0.08 -0.56 -0.04 1.21 0.53 3knkW1 ILE 103 HG23 -0.02 -0.01 -0.21 -0.04 0.93 0.65 3knkW1 ILE 103 HD13 -0.04 0.00 -0.18 -0.04 0.88 0.63 3knkW1 THR 104 H -0.19 0.41 0.24 -0.55 8.28 8.20 3knkW1 THR 104 HA -0.17 0.13 0.97 -0.75 4.39 4.56 3knkW1 THR 104 HB -1.01 0.12 0.10 -0.04 4.32 3.49 3knkW1 THR 104 HG23 -0.58 -0.00 -0.24 -0.04 1.22 0.35 3knkW1 VAL 105 H -0.12 0.28 0.08 -0.55 8.24 7.93 3knkW1 VAL 105 HA -0.09 0.16 0.94 -0.75 4.13 4.38 3knkW1 VAL 105 HB -0.04 0.02 -0.07 -0.04 2.12 1.99 3knkW1 VAL 105 HG13 -0.03 -0.00 -0.18 -0.04 0.97 0.71 3knkW1 VAL 105 HG23 -0.05 -0.02 -0.26 -0.04 0.95 0.58 3knkW1 ILE 106 H -0.04 0.43 0.11 -0.55 8.25 8.20 3knkW1 ILE 106 HA -0.01 0.34 1.06 -0.75 4.18 4.82 3knkW1 ILE 106 HB 0.02 0.05 -0.10 -0.04 1.89 1.81 3knkW1 ILE 106 HG12 0.01 0.59 0.28 -0.04 1.49 2.32 3knkW1 ILE 106 HG13 0.02 -0.18 0.13 -0.04 1.21 1.13 3knkW1 ILE 106 HG23 0.00 -0.03 -0.16 -0.04 0.93 0.70 3knkW1 ILE 106 HD13 0.11 -0.03 -0.10 -0.04 0.88 0.82 3knkW1 LEU 107 H 0.02 0.28 0.10 -0.55 8.37 8.22 3knkW1 LEU 107 HA 0.04 -0.06 0.81 -0.75 4.35 4.38 3knkW1 LEU 107 HB2 0.05 0.02 0.11 -0.04 1.64 1.78 3knkW1 LEU 107 HB3 0.09 0.09 0.07 -0.04 1.64 1.85 3knkW1 LEU 107 HG 0.03 -0.02 -0.10 -0.04 1.64 1.51 3knkW1 LEU 107 HD13 0.00 -0.01 -0.19 -0.04 0.93 0.69 3knkW1 LEU 107 HD23 0.03 0.03 -0.29 -0.04 0.89 0.61 3knkW1 GLY 108 H 0.27 0.22 0.37 -0.55 8.43 8.75 3knkW1 GLY 108 HA2 0.11 0.22 1.05 -0.51 4.01 4.88 3knkW1 GLY 108 HA3 0.30 0.02 0.38 -0.51 4.01 4.19 3knkW1 GLU 109 H 0.04 0.22 0.19 -0.55 8.60 8.52 3knkW1 GLU 109 HA -0.05 0.23 0.49 -0.75 4.29 4.20 3knkW1 GLU 109 HB2 -0.04 0.03 0.10 -0.04 2.09 2.14 3knkW1 GLU 109 HB3 -0.08 -0.27 0.16 -0.04 1.99 1.77 3knkW1 GLU 109 HG2 -0.01 0.10 0.15 -0.04 2.34 2.54 3knkW1 GLU 109 HG3 -0.02 0.05 0.12 -0.04 2.34 2.45 3knkW1 LYS 110 H -0.13 0.04 0.16 -0.55 8.42 7.93 3knkW1 LYS 110 HA -0.30 0.16 0.58 -0.75 4.32 4.00 3knkW1 LYS 110 HB2 -0.11 0.05 0.20 -0.04 1.87 1.97 3knkW1 LYS 110 HB3 -0.19 -0.21 0.13 -0.04 1.79 1.47 3knkW1 LYS 110 HG2 -0.00 -0.06 0.01 -0.04 1.46 1.37 3knkW1 LYS 110 HG3 0.19 0.02 -0.03 -0.04 1.46 1.59 3knkW1 LYS 110 HD2 -0.11 0.12 -0.34 -0.04 1.69 1.33 3knkW1 LYS 110 HD3 -0.04 -0.30 -0.22 -0.04 1.68 1.08 3knkW1 LYS 110 HE2 0.03 -0.02 0.04 -0.04 2.99 2.99 3knkW1 LYS 110 HE3 0.05 -0.04 -0.02 -0.04 2.99 2.94 3knkW1 HIS 111 H -0.15 0.03 -0.02 -0.55 8.41 7.73 3knkW1 HIS 111 HA -0.07 0.12 0.32 -0.75 4.63 4.24 3knkW1 HIS 111 HB2 -0.04 0.02 -0.02 -0.04 3.26 3.18 3knkW1 HIS 111 HB3 -0.07 0.24 0.25 -0.04 3.20 3.58 3knkW1 HIS 111 HD2 -0.03 0.08 -0.19 -0.04 6.97 6.79 3knkW1 HIS 111 HE1 -0.05 0.03 -0.06 -0.04 7.75 7.63 3knkW1 GLY 112 H -1.11 0.03 0.04 -0.55 8.43 6.84 3knkW1 GLY 112 HA2 -0.23 -0.00 0.36 -0.51 4.01 3.63 3knkW1 GLY 112 HA3 -0.12 0.28 0.92 -0.51 4.01 4.58 3knkW1 LYS 113 H -0.40 0.03 0.07 -0.55 8.42 7.57 3knkW1 LYS 113 HA -0.00 0.09 0.16 -0.75 4.32 3.82