#PDB cf residue atom bb_p bb_s bb_f chi_p chi_s HB-D HB-I REF pred #--------------------------------------------------------------------------------------------- 2kw2 s THR 2 N 0.00 3.73 0.14 2.03 2.01 -1.26 -5.02 115.64 117.28 2kw2 s THR 2 Ca 0.00 0.71 -0.15 0.00 0.31 0.00 0.00 61.69 62.56 2kw2 s THR 2 Cb 0.00 -4.09 -0.07 0.00 0.01 0.00 0.00 72.50 68.35 2kw2 s THR 2 CO 0.00 -0.76 0.57 -0.55 -0.69 0.00 0.00 174.62 173.19 2kw2 s SER 3 N 4.88 6.88 0.50 3.53 0.15 -1.26 -4.99 113.70 123.38 2kw2 s SER 3 Ca 0.65 1.13 0.25 0.00 0.70 0.00 0.00 55.95 58.68 2kw2 s SER 3 Cb -0.15 -2.31 1.32 0.00 -1.71 0.00 0.00 66.02 63.17 2kw2 s SER 3 CO 0.31 0.12 2.02 0.74 1.20 0.00 0.00 173.24 177.63 2kw2 h THR 4 N 2.90 0.63 -0.06 6.45 2.02 -1.95 -2.44 112.91 120.46 2kw2 h THR 4 Ca -0.49 -0.66 -0.22 0.00 0.77 0.00 0.00 66.41 65.81 2kw2 h THR 4 Cb 1.20 1.42 0.01 0.00 -1.74 0.00 0.00 68.15 69.03 2kw2 h THR 4 CO 0.65 0.15 -0.86 0.15 0.37 0.00 0.00 175.52 175.98 2kw2 h PHE 5 N 0.00 0.77 -0.43 3.16 3.57 -1.92 -3.12 116.94 118.97 2kw2 h PHE 5 Ca -0.00 -0.38 0.08 0.00 3.53 0.00 0.00 57.97 61.20 2kw2 h PHE 5 Cb 0.41 -0.10 -0.08 0.00 2.79 0.00 0.00 35.95 38.97 2kw2 h PHE 5 CO 0.00 1.19 -0.05 0.22 -2.23 0.00 0.00 178.31 177.44 2kw2 h ASP 6 N 0.34 -0.28 -0.19 0.41 3.58 -1.83 0.19 116.42 118.64 2kw2 h ASP 6 Ca -0.07 0.11 -0.03 0.00 0.42 0.00 0.00 57.03 57.47 2kw2 h ASP 6 Cb 1.48 0.22 -0.01 0.00 1.72 0.00 0.00 39.33 42.74 2kw2 h ASP 6 CO 0.16 -0.09 0.02 0.03 -2.88 0.00 0.00 179.24 176.47 2kw2 h ARG 7 N 0.06 0.32 -0.64 0.28 2.47 -1.64 -2.74 114.38 112.49 2kw2 h ARG 7 Ca 0.21 -0.09 0.01 0.00 -1.26 0.00 0.00 59.98 58.85 2kw2 h ARG 7 Cb 0.32 -0.03 -0.03 0.00 -1.65 0.00 0.00 29.97 28.57 2kw2 h ARG 7 CO -0.40 0.50 0.43 0.28 0.56 0.00 0.00 179.97 181.34 2kw2 h VAL 8 N 0.10 1.14 -0.62 2.04 2.07 -1.36 -2.29 116.25 117.33 2kw2 h VAL 8 Ca 0.06 -0.29 -0.06 0.00 0.82 0.00 0.00 66.70 67.23 2kw2 h VAL 8 Cb 0.35 0.23 -0.02 0.00 -1.52 0.00 0.00 31.29 30.32 2kw2 h VAL 8 CO 0.01 0.15 0.14 0.00 0.02 0.00 0.00 177.57 177.89 2kw2 h ALA 9 N 1.61 0.81 -0.38 1.67 0.00 -0.49 -1.06 119.26 121.42 2kw2 h ALA 9 Ca 0.24 -0.24 0.04 0.00 0.00 0.00 0.00 54.91 54.95 2kw2 h ALA 9 Cb -0.05 -0.23 -0.04 0.00 0.00 0.00 0.00 17.79 17.47 2kw2 h ALA 9 CO -0.06 0.53 0.16 1.15 0.00 0.00 0.00 179.25 181.04 2kw2 h THR 10 N 0.90 0.93 -0.01 0.00 2.02 -1.18 -2.27 112.91 113.31 2kw2 h THR 10 Ca 0.19 -0.12 -0.00 0.00 0.77 0.00 0.00 66.41 67.25 2kw2 h THR 10 Cb 0.37 0.56 -0.00 0.00 -1.74 0.00 0.00 68.15 67.34 2kw2 h THR 10 CO 0.00 0.06 -0.00 0.40 0.37 0.00 0.00 175.52 176.36 2kw2 h ILE 11 N 0.34 1.26 -0.42 3.11 2.04 -0.90 -2.24 117.51 120.70 2kw2 h ILE 11 Ca 0.17 -0.78 -0.05 0.00 1.00 0.00 0.00 64.86 65.20 2kw2 h ILE 11 Cb 0.11 1.78 -0.02 0.00 -0.74 0.00 0.00 36.82 37.95 2kw2 h ILE 11 CO -0.15 0.20 0.05 0.40 0.00 0.00 0.00 178.15 178.66 2kw2 h ILE 12 N -0.31 1.21 0.30 -0.67 2.04 -1.30 -1.13 117.51 117.65 2kw2 h ILE 12 Ca 0.00 -0.79 -0.00 0.00 1.00 0.00 0.00 64.86 65.07 2kw2 h ILE 12 Cb 0.33 0.83 -0.02 0.00 -0.74 0.00 0.00 36.82 37.23 2kw2 h ILE 12 CO 0.00 0.28 -0.29 0.00 0.00 0.00 0.00 178.15 178.14 2kw2 h ALA 13 N 1.44 -0.62 0.00 1.87 0.00 -1.25 -1.01 119.26 119.69 2kw2 h ALA 13 Ca 0.14 -0.10 -0.16 0.00 0.00 0.00 0.00 54.91 54.79 2kw2 h ALA 13 Cb 0.31 0.41 -0.02 0.00 0.00 0.00 0.00 17.79 18.50 2kw2 h ALA 13 CO 0.01 -0.88 -0.78 0.93 0.00 0.00 0.00 179.25 178.53 2kw2 h GLU 14 N -0.62 0.00 0.31 0.00 4.39 -1.27 -1.27 114.58 116.12 2kw2 h GLU 14 Ca -0.01 0.00 -0.02 0.00 0.34 0.00 0.00 59.36 59.67 2kw2 h GLU 14 Cb 0.56 0.00 0.00 0.00 -0.10 0.00 0.00 28.75 29.22 2kw2 h GLU 14 CO -0.05 0.78 -0.15 1.15 -1.16 0.00 0.00 179.01 179.58 2kw2 h THR 15 N 0.00 0.00 -0.00 1.13 2.02 -1.24 -3.37 112.91 111.44 2kw2 h THR 15 Ca -0.01 -0.49 0.00 0.00 0.77 0.00 0.00 66.41 66.68 2kw2 h THR 15 Cb 1.46 0.00 0.00 0.00 -1.74 0.00 0.00 68.15 67.87 2kw2 h THR 15 CO 0.10 0.00 -0.02 0.00 0.37 0.00 0.00 175.52 175.97 2kw2 n ASP 17 N -0.70 -6.72 -4.13 0.00 2.03 -0.58 -5.04 116.55 101.41 2kw2 n ASP 17 Ca 0.21 -0.63 -0.24 0.00 0.52 0.00 0.00 54.79 54.64 2kw2 n ASP 17 Cb 0.21 -5.04 -0.15 0.00 -0.72 0.00 0.00 41.12 35.41 2kw2 n ASP 17 CO 0.00 0.00 0.00 -0.63 -1.92 0.00 0.00 177.20 174.65 2kw2 s ILE 18 N -3.33 1.27 -0.08 5.18 1.01 -0.60 -5.06 121.20 119.60 2kw2 s ILE 18 Ca 0.38 -0.67 -0.36 0.00 0.00 0.00 0.00 60.65 60.00 2kw2 s ILE 18 Cb -0.06 -1.07 -0.14 0.00 0.01 0.00 0.00 42.46 41.20 2kw2 s ILE 18 CO 0.75 0.36 1.72 -0.81 0.00 0.00 0.00 174.94 176.97 2kw2 n PRO 19 N 2.86 1.74 -0.33 2.79 -0.04 -1.26 -4.46 135.00 136.30 2kw2 n PRO 19 Ca -0.16 0.63 -0.03 0.00 -0.04 0.00 0.00 63.50 63.91 2kw2 n PRO 19 Cb 0.54 -2.39 0.10 0.00 -0.04 0.00 0.00 33.50 31.70 2kw2 n PRO 19 CO 0.00 0.00 0.00 -0.09 -0.04 0.00 0.00 175.50 175.37 2kw2 h ARG 20 N 7.48 1.14 0.00 0.54 1.12 -1.92 -2.83 114.38 119.91 2kw2 h ARG 20 Ca -0.47 -0.07 -0.11 0.00 -1.11 0.00 0.00 59.98 58.22 2kw2 h ARG 20 Cb 1.29 -0.26 -0.02 0.00 -0.01 0.00 0.00 29.97 30.98 2kw2 h ARG 20 CO 0.92 0.76 -0.51 1.05 -3.11 0.00 0.00 179.97 179.07 2kw2 h GLU 21 N 1.18 0.00 0.00 0.20 4.11 -1.93 -3.06 114.58 115.08 2kw2 h GLU 21 Ca 0.33 0.00 -0.11 0.00 0.07 0.00 0.00 59.36 59.65 2kw2 h GLU 21 Cb -0.09 0.00 -0.02 0.00 0.50 0.00 0.00 28.75 29.14 2kw2 h GLU 21 CO -0.09 0.51 -0.56 1.79 0.07 0.00 0.00 179.01 180.74 2kw2 h THR 22 N 0.00 0.91 -1.67 -1.06 1.35 -1.90 -3.44 112.91 107.10 2kw2 h THR 22 Ca -0.01 -2.30 -0.62 0.00 -0.55 0.00 0.00 66.41 62.94 2kw2 h THR 22 Cb 0.94 2.45 -0.00 0.00 -1.73 0.00 0.00 68.15 69.80 2kw2 h THR 22 CO 0.07 0.52 1.43 -0.38 -0.25 0.00 0.00 175.52 176.91 2kw2 n ILE 23 N -3.23 0.31 -3.61 6.82 5.41 -1.16 -4.98 119.36 118.93 2kw2 n ILE 23 Ca 0.02 -0.36 -0.33 0.00 1.00 0.00 0.00 62.75 63.07 2kw2 n ILE 23 Cb 0.75 -2.18 -0.05 0.00 -0.71 0.00 0.00 39.64 37.45 2kw2 n ILE 23 CO 0.00 0.00 0.00 0.42 0.00 0.00 0.00 176.55 176.97 2kw2 s THR 24 N 7.58 5.12 0.42 1.39 -4.23 -1.26 -5.01 115.64 119.65 2kw2 s THR 24 Ca 1.03 0.29 0.17 0.00 -1.18 0.00 0.00 61.69 62.00 2kw2 s THR 24 Cb -0.55 -3.63 0.18 0.00 1.34 0.00 0.00 72.50 69.84 2kw2 s THR 24 CO 0.42 0.18 1.96 1.55 -0.54 0.00 0.00 174.62 178.18 2kw2 h PRO 25 N 3.34 0.00 0.00 3.99 0.13 -1.94 -2.97 132.00 134.54 2kw2 h PRO 25 Ca -0.48 0.00 0.00 0.00 -0.87 0.00 0.00 66.00 64.65 2kw2 h PRO 25 Cb 1.18 0.00 0.00 0.00 0.13 0.00 0.00 31.00 32.31 2kw2 h PRO 25 CO 0.69 0.22 0.00 -0.85 -0.23 0.00 0.00 178.00 177.83 2kw2 n GLU 26 N -4.11 0.06 -2.48 0.86 0.28 -1.26 -0.82 120.64 113.18 2kw2 n GLU 26 Ca -0.02 0.06 -0.40 0.00 -0.16 0.00 0.00 57.16 56.64 2kw2 n GLU 26 Cb 0.29 -1.57 -0.04 0.00 1.43 0.00 0.00 31.44 31.55 2kw2 n GLU 26 CO 0.00 0.00 0.00 -1.54 -0.16 0.00 0.00 177.13 175.43 2kw2 s SER 27 N -3.34 7.23 -0.10 -1.84 1.04 -1.12 -4.83 113.70 110.73 2kw2 s SER 27 Ca 0.13 2.26 -0.19 0.00 0.48 0.00 0.00 55.95 58.63 2kw2 s SER 27 Cb 0.17 -2.62 -0.04 0.00 0.10 0.00 0.00 66.02 63.62 2kw2 s SER 27 CO 0.53 -0.17 0.52 -2.28 0.98 0.00 0.00 173.24 172.82 2kw2 s HIS 28 N -1.19 3.54 0.11 5.02 2.46 -1.26 -1.56 115.29 122.40 2kw2 s HIS 28 Ca 0.45 0.97 -0.29 0.00 0.47 0.00 0.00 55.06 56.66 2kw2 s HIS 28 Cb -0.31 -2.59 -0.11 0.00 -0.13 0.00 0.00 32.58 29.44 2kw2 s HIS 28 CO 0.40 0.17 1.48 0.00 -2.47 0.00 0.00 174.74 174.33 2kw2 h ALA 29 N 6.63 -0.79 -0.03 1.58 0.00 -1.59 -0.31 119.26 124.74 2kw2 h ALA 29 Ca -0.41 -0.03 -0.13 0.00 0.00 0.00 0.00 54.91 54.33 2kw2 h ALA 29 Cb 1.18 1.01 0.01 0.00 0.00 0.00 0.00 17.79 19.99 2kw2 h ALA 29 CO 0.75 -0.99 -0.50 0.82 0.00 0.00 0.00 179.25 179.33 2kw2 h ILE 30 N -0.44 1.43 0.20 0.00 2.04 -1.84 -0.20 117.51 118.70 2kw2 h ILE 30 Ca 0.04 -1.95 -0.01 0.00 1.00 0.00 0.00 64.86 63.94 2kw2 h ILE 30 Cb 0.56 2.48 0.00 0.00 -0.74 0.00 0.00 36.82 39.13 2kw2 h ILE 30 CO -0.44 0.57 -0.10 -0.78 0.00 0.00 0.00 178.15 177.40 2kw2 h ASP 31 N -0.11 -0.23 0.22 1.72 3.58 -1.87 -3.00 116.42 116.73 2kw2 h ASP 31 Ca -0.05 0.01 -0.01 0.00 0.42 0.00 0.00 57.03 57.39 2kw2 h ASP 31 Cb 1.19 0.06 0.00 0.00 1.72 0.00 0.00 39.33 42.30 2kw2 h ASP 31 CO 0.10 -0.04 -0.11 -0.78 -2.88 0.00 0.00 179.24 175.53 2kw2 h ASP 32 N -0.53 -0.25 0.74 2.28 1.82 -1.28 -3.34 116.42 115.87 2kw2 h ASP 32 Ca -0.03 0.01 0.00 0.00 -0.39 0.00 0.00 57.03 56.62 2kw2 h ASP 32 Cb 0.21 0.06 0.00 0.00 0.68 0.00 0.00 39.33 40.28 2kw2 h ASP 32 CO 0.05 0.07 0.00 0.18 -1.61 0.00 0.00 179.24 177.92 2kw2 n LEU 33 N -4.14 0.16 -0.99 2.28 4.77 -0.72 -4.89 117.00 113.48 2kw2 n LEU 33 Ca -0.04 0.53 -0.13 0.00 -0.03 0.00 0.00 56.01 56.35 2kw2 n LEU 33 Cb 0.12 -0.50 -0.05 0.00 -2.33 0.00 0.00 43.42 40.66 2kw2 n LEU 33 CO 0.09 -0.22 -0.12 0.61 -1.33 0.00 0.00 177.39 176.41 2kw2 n GLY 34 N 0.50 1.32 3.72 -0.72 0.00 -0.45 -4.95 105.19 104.61 2kw2 n GLY 34 Ca 0.04 -0.43 -0.42 0.00 0.00 0.00 0.00 46.02 45.21 2kw2 n GLY 34 CO 0.00 0.00 0.00 -0.42 0.00 0.00 0.00 173.32 172.90 2kw2 s ILE 35 N -2.48 3.49 0.51 -0.61 1.01 -0.21 -4.93 121.20 117.98 2kw2 s ILE 35 Ca 0.00 1.08 -0.20 0.00 0.00 0.00 0.00 60.65 61.52 2kw2 s ILE 35 Cb 0.00 -3.69 -0.07 0.00 0.01 0.00 0.00 42.46 38.71 2kw2 s ILE 35 CO 0.00 0.09 1.11 -0.62 0.00 0.00 0.00 174.94 175.52 2kw2 s ASP 36 N 1.05 5.97 0.43 3.58 -1.08 -1.26 -3.88 116.67 121.47 2kw2 s ASP 36 Ca 0.63 2.14 0.30 0.00 -0.52 0.00 0.00 52.55 55.09 2kw2 s ASP 36 Cb -0.35 -2.58 1.36 0.00 -1.46 0.00 0.00 42.92 39.89 2kw2 s ASP 36 CO 0.30 -1.05 1.90 -1.28 0.52 0.00 0.00 175.17 175.56 2kw2 h SER 37 N 1.46 0.00 0.70 -0.34 0.87 -1.98 0.09 113.55 114.34 2kw2 h SER 37 Ca -0.50 0.00 -0.26 0.00 -1.23 0.00 0.00 61.79 59.80 2kw2 h SER 37 Cb 1.25 0.00 -0.03 0.00 -0.44 0.00 0.00 62.40 63.18 2kw2 h SER 37 CO 0.58 0.00 -1.36 -0.07 -0.53 0.00 0.00 176.83 175.45 2kw2 h LEU 38 N 0.00 0.11 -0.25 2.23 3.38 -2.02 -3.26 115.31 115.50 2kw2 h LEU 38 Ca 0.00 -0.15 -0.18 0.00 0.09 0.00 0.00 57.88 57.64 2kw2 h LEU 38 Cb 0.31 -0.03 -0.03 0.00 0.09 0.00 0.00 40.66 41.00 2kw2 h LEU 38 CO 0.00 1.12 -0.88 -0.78 0.09 0.00 0.00 178.44 177.99 2kw2 h ASP 39 N 0.02 0.02 0.67 -0.43 3.58 -1.67 -3.11 116.42 115.49 2kw2 h ASP 39 Ca -0.16 -0.01 -0.01 0.00 0.42 0.00 0.00 57.03 57.27 2kw2 h ASP 39 Cb 1.91 -0.00 -0.00 0.00 1.72 0.00 0.00 39.33 42.95 2kw2 h ASP 39 CO 0.12 0.88 -0.05 0.15 -2.88 0.00 0.00 179.24 177.46 2kw2 h PHE 40 N 0.01 0.00 -0.98 0.28 3.57 -1.11 -2.31 116.94 116.39 2kw2 h PHE 40 Ca -0.01 0.00 0.02 0.00 3.53 0.00 0.00 57.97 61.50 2kw2 h PHE 40 Cb 1.55 0.00 -0.05 0.00 2.79 0.00 0.00 35.95 40.24 2kw2 h PHE 40 CO 0.00 0.05 0.65 -0.07 -2.23 0.00 0.00 178.31 176.71 2kw2 h LEU 41 N 0.00 1.11 -0.66 0.59 3.38 -1.58 -1.06 115.31 117.09 2kw2 h LEU 41 Ca -0.00 -0.02 -0.13 0.00 0.09 0.00 0.00 57.88 57.81 2kw2 h LEU 41 Cb 0.40 -0.27 -0.01 0.00 0.09 0.00 0.00 40.66 40.87 2kw2 h LEU 41 CO 0.01 0.80 -0.41 -0.78 0.09 0.00 0.00 178.44 178.14 2kw2 h ASP 42 N 1.31 0.60 -0.15 -0.43 1.82 -1.58 -1.42 116.42 116.57 2kw2 h ASP 42 Ca 0.37 -0.27 -0.00 0.00 -0.39 0.00 0.00 57.03 56.73 2kw2 h ASP 42 Cb -0.12 -0.17 -0.01 0.00 0.68 0.00 0.00 39.33 39.71 2kw2 h ASP 42 CO -0.09 0.94 0.08 0.40 -1.61 0.00 0.00 179.24 178.96 2kw2 h ILE 43 N 0.46 1.11 -0.12 2.25 2.04 -1.41 -1.34 117.51 120.50 2kw2 h ILE 43 Ca 0.04 -0.31 -0.06 0.00 1.00 0.00 0.00 64.86 65.53 2kw2 h ILE 43 Cb 0.92 1.04 -0.01 0.00 -0.74 0.00 0.00 36.82 38.03 2kw2 h ILE 43 CO 0.08 0.10 -0.19 0.00 0.00 0.00 0.00 178.15 178.14 2kw2 h ALA 44 N 0.96 1.45 -0.28 1.87 0.00 -1.10 -0.37 119.26 121.78 2kw2 h ALA 44 Ca 0.05 -0.24 -0.15 0.00 0.00 0.00 0.00 54.91 54.57 2kw2 h ALA 44 Cb 0.09 -0.08 -0.00 0.00 0.00 0.00 0.00 17.79 17.80 2kw2 h ALA 44 CO -0.01 0.39 -0.39 0.35 0.00 0.00 0.00 179.25 179.59 2kw2 h PHE 45 N 0.19 0.94 0.00 0.00 3.57 -1.07 -1.13 116.94 119.45 2kw2 h PHE 45 Ca 0.04 -0.31 -0.12 0.00 3.53 0.00 0.00 57.97 61.11 2kw2 h PHE 45 Cb 0.46 -0.19 -0.02 0.00 2.79 0.00 0.00 35.95 38.99 2kw2 h PHE 45 CO 0.01 1.09 -0.57 0.00 -2.23 0.00 0.00 178.31 176.61 2kw2 h ALA 46 N 0.68 0.82 -0.24 2.41 0.00 -0.81 -2.31 119.26 119.81 2kw2 h ALA 46 Ca 0.03 -0.51 -0.13 0.00 0.00 0.00 0.00 54.91 54.30 2kw2 h ALA 46 Cb 0.98 -0.09 -0.00 0.00 0.00 0.00 0.00 17.79 18.68 2kw2 h ALA 46 CO 0.09 0.71 -0.36 0.82 0.00 0.00 0.00 179.25 180.51 2kw2 h ILE 47 N 0.00 1.31 -0.99 0.00 2.04 -1.08 -0.97 117.51 117.83 2kw2 h ILE 47 Ca -0.01 -1.56 0.08 0.00 1.00 0.00 0.00 64.86 64.38 2kw2 h ILE 47 Cb 1.19 1.74 -0.07 0.00 -0.74 0.00 0.00 36.82 38.93 2kw2 h ILE 47 CO 0.07 0.49 0.63 -0.78 0.00 0.00 0.00 178.15 178.56 2kw2 h ASP 48 N 0.38 0.97 0.00 1.72 1.82 -1.04 -1.54 116.42 118.73 2kw2 h ASP 48 Ca 0.02 0.02 -0.03 0.00 -0.39 0.00 0.00 57.03 56.66 2kw2 h ASP 48 Cb 0.94 -0.18 0.00 0.00 0.68 0.00 0.00 39.33 40.78 2kw2 h ASP 48 CO 0.08 0.59 -0.13 0.11 -1.61 0.00 0.00 179.24 178.28 2kw2 h LYS 49 N 1.09 0.08 0.01 0.28 1.57 -1.43 -2.43 116.57 115.73 2kw2 h LYS 49 Ca 0.45 -0.09 -0.00 0.00 -1.87 0.00 0.00 60.65 59.14 2kw2 h LYS 49 Cb 0.28 0.03 0.00 0.00 0.08 0.00 0.00 32.23 32.62 2kw2 h LYS 49 CO -0.21 0.88 -0.00 0.00 -0.57 0.00 0.00 179.45 179.55 2kw2 h ALA 50 N 0.20 -0.01 0.00 3.86 0.00 -0.93 -2.94 119.26 119.44 2kw2 h ALA 50 Ca -0.02 -0.10 -0.06 0.00 0.00 0.00 0.00 54.91 54.74 2kw2 h ALA 50 Cb 0.93 0.00 -0.01 0.00 0.00 0.00 0.00 17.79 18.71 2kw2 h ALA 50 CO 0.02 -0.41 -0.56 0.74 0.00 0.00 0.00 179.25 179.05 2kw2 h PHE 51 N -0.20 0.00 -1.57 0.00 -1.00 -1.49 -3.48 116.94 109.19 2kw2 h PHE 51 Ca -0.00 0.00 -0.13 0.00 2.81 0.00 0.00 57.97 60.65 2kw2 h PHE 51 Cb 0.20 0.00 0.01 0.00 3.61 0.00 0.00 35.95 39.77 2kw2 h PHE 51 CO -0.01 0.24 -0.19 0.41 -1.61 0.00 0.00 178.31 177.15 2kw2 n GLY 52 N 1.20 0.24 3.59 -1.45 0.00 -0.97 -5.03 105.19 102.76 2kw2 n GLY 52 Ca 0.01 -0.52 -0.24 0.00 0.00 0.00 0.00 46.02 45.27 2kw2 n GLY 52 CO 0.00 0.00 0.00 -0.26 0.00 0.00 0.00 173.32 173.06 2kw2 s ILE 53 N -2.63 3.17 -0.67 -0.61 -4.36 -0.96 -5.02 121.20 110.13 2kw2 s ILE 53 Ca 0.07 -1.98 -0.20 0.00 -0.26 0.00 0.00 60.65 58.27 2kw2 s ILE 53 Cb -0.03 -2.66 0.09 0.00 1.25 0.00 0.00 42.46 41.11 2kw2 s ILE 53 CO 0.09 -0.33 0.88 -0.75 0.24 0.00 0.00 174.94 175.06 2kw2 s LYS 54 N -3.47 3.15 -0.54 0.37 2.20 -1.26 -4.36 119.74 115.82 2kw2 s LYS 54 Ca 0.30 -1.18 -0.23 0.00 -0.36 0.00 0.00 55.97 54.50 2kw2 s LYS 54 Cb -0.07 -4.33 0.05 0.00 -1.51 0.00 0.00 37.83 31.97 2kw2 s LYS 54 CO 0.18 -1.69 0.85 -1.17 -0.36 0.00 0.00 175.35 173.16 2kw2 s LEU 55 N 3.26 4.34 -1.24 5.43 0.20 -1.26 -5.00 118.68 124.41 2kw2 s LEU 55 Ca 0.19 -0.51 -0.17 0.00 0.69 0.00 0.00 54.13 54.33 2kw2 s LEU 55 Cb -0.18 -2.72 0.10 0.00 -0.43 0.00 0.00 46.19 42.96 2kw2 s LEU 55 CO 0.06 -1.13 1.60 -2.16 -0.29 0.00 0.00 176.35 174.43 2kw2 s PRO 56 N 3.58 3.99 0.21 0.98 0.04 -1.26 -4.74 135.00 137.81 2kw2 s PRO 56 Ca 0.26 -2.13 0.10 0.00 0.04 0.00 0.00 61.00 59.27 2kw2 s PRO 56 Cb -0.14 -5.36 0.13 0.00 0.04 0.00 0.00 34.50 29.17 2kw2 s PRO 56 CO 0.17 -2.08 1.47 1.25 0.04 0.00 0.00 177.00 177.85 2kw2 h LEU 57 N 11.59 0.00 -2.02 -3.56 5.85 -1.96 -1.38 115.31 123.83 2kw2 h LEU 57 Ca 0.38 0.00 0.05 0.00 0.84 0.00 0.00 57.88 59.15 2kw2 h LEU 57 Cb 0.88 0.00 -0.01 0.00 0.37 0.00 0.00 40.66 41.91 2kw2 h LEU 57 CO 1.38 0.76 0.12 1.05 -0.34 0.00 0.00 178.44 181.41 2kw2 h GLU 58 N 0.00 0.00 0.03 1.25 4.11 -2.00 -0.42 114.58 117.55 2kw2 h GLU 58 Ca -0.01 0.00 -0.14 0.00 0.07 0.00 0.00 59.36 59.28 2kw2 h GLU 58 Cb 1.38 0.00 -0.01 0.00 0.50 0.00 0.00 28.75 30.62 2kw2 h GLU 58 CO 0.10 0.00 -0.72 -0.22 0.07 0.00 0.00 179.01 178.24 2kw2 h LYS 59 N 0.00 0.07 -0.85 1.06 3.64 -1.88 -3.26 116.57 115.34 2kw2 h LYS 59 Ca 0.08 -0.11 -0.02 0.00 -1.27 0.00 0.00 60.65 59.33 2kw2 h LYS 59 Cb 0.33 0.04 -0.04 0.00 -0.41 0.00 0.00 32.23 32.15 2kw2 h LYS 59 CO -0.00 1.05 0.46 -1.49 -2.27 0.00 0.00 179.45 177.20 2kw2 h TRP 60 N -0.83 1.17 -0.54 1.91 6.55 -0.85 0.10 115.95 123.46 2kw2 h TRP 60 Ca -0.18 -0.03 -0.01 0.00 0.95 0.00 0.00 58.89 59.62 2kw2 h TRP 60 Cb 1.28 -0.37 -0.03 0.00 -0.86 0.00 0.00 29.16 29.18 2kw2 h TRP 60 CO 0.19 0.81 0.29 1.15 -1.05 0.00 0.00 178.44 179.82 2kw2 h THR 61 N 1.19 1.19 -0.02 1.49 2.02 -1.30 -3.09 112.91 114.39 2kw2 h THR 61 Ca 0.30 -0.49 -0.06 0.00 0.77 0.00 0.00 66.41 66.92 2kw2 h THR 61 Cb 0.03 0.52 -0.01 0.00 -1.74 0.00 0.00 68.15 66.95 2kw2 h THR 61 CO -0.05 0.20 -0.28 -0.61 0.37 0.00 0.00 175.52 175.16 2kw2 h GLN 62 N 0.73 0.04 -0.29 6.66 5.75 -1.06 -1.05 115.11 125.89 2kw2 h GLN 62 Ca 0.19 -0.01 -0.01 0.00 -0.15 0.00 0.00 58.65 58.67 2kw2 h GLN 62 Cb 0.07 -0.00 -0.01 0.00 1.07 0.00 0.00 27.48 28.60 2kw2 h GLN 62 CO -0.03 0.32 0.15 0.93 -2.65 0.00 0.00 178.83 177.55 2kw2 h GLU 63 N 0.03 0.41 -0.43 1.69 4.39 -0.82 0.11 114.58 119.96 2kw2 h GLU 63 Ca 0.00 -0.06 -0.02 0.00 0.34 0.00 0.00 59.36 59.63 2kw2 h GLU 63 Cb 0.52 -0.08 -0.02 0.00 -0.10 0.00 0.00 28.75 29.07 2kw2 h GLU 63 CO 0.04 0.38 0.20 0.28 -1.16 0.00 0.00 179.01 178.75 2kw2 h VAL 64 N 0.34 1.18 0.00 3.13 2.07 -1.35 0.25 116.25 121.87 2kw2 h VAL 64 Ca 0.10 -0.54 -0.06 0.00 0.82 0.00 0.00 66.70 67.03 2kw2 h VAL 64 Cb 0.10 0.74 -0.01 0.00 -1.52 0.00 0.00 31.29 30.60 2kw2 h VAL 64 CO -0.01 0.20 -0.27 0.78 0.02 0.00 0.00 177.57 178.29 2kw2 h ASN 65 N 0.56 0.00 1.02 0.57 2.35 -1.02 -2.71 115.58 116.34 2kw2 h ASN 65 Ca 0.15 0.00 0.00 0.00 -0.55 0.00 0.00 56.30 55.90 2kw2 h ASN 65 Cb 0.14 0.00 0.00 0.00 0.05 0.00 0.00 38.32 38.51 2kw2 h ASN 65 CO -0.02 0.27 -0.86 -0.78 -1.65 0.00 0.00 177.43 174.40 2kw2 h ASP 66 N 0.00 0.00 0.00 5.81 3.58 -0.60 -3.48 116.42 121.73 2kw2 h ASP 66 Ca -0.00 -0.06 0.00 0.00 0.42 0.00 0.00 57.03 57.39 2kw2 h ASP 66 Cb 0.51 0.00 0.00 0.00 1.72 0.00 0.00 39.33 41.56 2kw2 h ASP 66 CO 0.04 0.03 0.00 0.61 -2.88 0.00 0.00 179.24 177.03 2kw2 n GLY 67 N 1.21 0.74 0.21 -0.78 0.00 -0.49 -4.96 105.19 101.13 2kw2 n GLY 67 Ca 0.01 -0.00 -0.02 0.00 0.00 0.00 0.00 46.02 46.01 2kw2 n GLY 67 CO 0.00 0.00 0.00 0.50 0.00 0.00 0.00 173.32 173.82 2kw2 h LYS 68 N 2.46 0.29 -4.76 1.61 1.79 -0.82 -3.47 116.57 113.68 2kw2 h LYS 68 Ca 0.00 -0.12 -0.28 0.00 -2.18 0.00 0.00 60.65 58.07 2kw2 h LYS 68 Cb 0.00 -0.01 -0.15 0.00 -1.58 0.00 0.00 32.23 30.49 2kw2 h LYS 68 CO 0.00 0.60 -0.66 0.00 -1.08 0.00 0.00 179.45 178.31 2kw2 s ALA 69 N -4.30 1.30 0.16 3.86 0.00 -0.81 -4.95 121.76 117.02 2kw2 s ALA 69 Ca -0.05 -1.58 0.05 0.00 0.00 0.00 0.00 51.96 50.38 2kw2 s ALA 69 Cb 0.14 0.57 -0.04 0.00 0.00 0.00 0.00 23.12 23.79 2kw2 s ALA 69 CO 0.77 -0.34 0.13 -0.08 0.00 0.00 0.00 175.76 176.25 2kw2 s THR 70 N -3.70 4.50 0.42 0.00 -1.32 -1.26 -4.06 115.64 110.23 2kw2 s THR 70 Ca 0.24 -1.05 0.10 0.00 -1.21 0.00 0.00 61.69 59.77 2kw2 s THR 70 Cb 0.06 -3.29 0.22 0.00 -1.51 0.00 0.00 72.50 67.98 2kw2 s THR 70 CO 0.04 -0.09 2.01 0.74 -2.21 0.00 0.00 174.62 175.11 2kw2 h THR 71 N 2.08 1.11 -0.87 5.08 2.02 -1.96 -2.39 112.91 117.99 2kw2 h THR 71 Ca -0.48 -0.42 0.02 0.00 0.77 0.00 0.00 66.41 66.31 2kw2 h THR 71 Cb 1.20 0.93 -0.05 0.00 -1.74 0.00 0.00 68.15 68.49 2kw2 h THR 71 CO 0.63 0.14 0.57 -0.08 0.37 0.00 0.00 175.52 177.16 2kw2 h GLU 72 N 0.29 1.10 -0.27 6.66 4.22 -1.96 -1.62 114.58 123.01 2kw2 h GLU 72 Ca 0.07 -0.07 0.01 0.00 0.08 0.00 0.00 59.36 59.45 2kw2 h GLU 72 Cb 0.15 -0.25 -0.01 0.00 0.50 0.00 0.00 28.75 29.14 2kw2 h GLU 72 CO -0.00 0.73 0.18 0.37 -2.18 0.00 0.00 179.01 178.11 2kw2 h GLN 73 N 1.14 0.34 0.00 1.92 4.15 -1.82 -3.00 115.11 117.84 2kw2 h GLN 73 Ca 0.33 -0.02 -0.05 0.00 0.77 0.00 0.00 58.65 59.68 2kw2 h GLN 73 Cb -0.07 -0.08 -0.01 0.00 0.21 0.00 0.00 27.48 27.54 2kw2 h GLN 73 CO -0.09 0.23 -0.91 0.66 -1.93 0.00 0.00 178.83 176.79 2kw2 n TYR 74 N -4.50 0.00 0.30 3.99 4.01 -1.21 -4.52 117.16 115.23 2kw2 n TYR 74 Ca 0.01 0.00 0.19 0.00 -0.16 0.00 0.00 57.90 57.94 2kw2 n TYR 74 Cb 0.08 -0.40 0.82 0.00 -0.31 0.00 0.00 39.34 39.53 2kw2 n TYR 74 CO 0.00 0.00 0.00 0.74 -0.46 0.00 0.00 176.86 177.14 2kw2 h PHE 75 N -0.70 0.00 -2.89 -0.72 -1.00 -1.38 -2.34 116.94 107.90 2kw2 h PHE 75 Ca -0.07 0.00 -0.53 0.00 2.81 0.00 0.00 57.97 60.18 2kw2 h PHE 75 Cb 0.81 0.00 0.03 0.00 3.61 0.00 0.00 35.95 40.40 2kw2 h PHE 75 CO -0.27 0.00 0.82 0.08 -1.61 0.00 0.00 178.31 177.34 2kw2 s VAL 76 N -3.78 2.96 0.29 -0.55 1.01 -1.13 -1.37 120.40 117.83 2kw2 s VAL 76 Ca -0.00 0.67 0.02 0.00 0.00 0.00 0.00 61.98 62.67 2kw2 s VAL 76 Cb 0.10 -3.43 0.09 0.00 0.00 0.00 0.00 36.38 33.14 2kw2 s VAL 76 CO 0.50 0.05 1.76 -0.07 0.00 0.00 0.00 175.10 177.33 2kw2 h LEU 77 N 6.96 0.51 -0.93 3.92 3.38 -1.22 0.48 115.31 128.41 2kw2 h LEU 77 Ca -0.42 -0.15 -0.07 0.00 0.09 0.00 0.00 57.88 57.32 2kw2 h LEU 77 Cb 1.21 -0.14 -0.02 0.00 0.09 0.00 0.00 40.66 41.80 2kw2 h LEU 77 CO 0.89 0.70 -0.03 0.07 0.09 0.00 0.00 178.44 180.17 2kw2 h LYS 78 N 0.47 0.75 -0.08 1.13 2.10 -1.25 -0.32 116.57 119.37 2kw2 h LYS 78 Ca 0.08 -0.21 -0.12 0.00 -2.00 0.00 0.00 60.65 58.40 2kw2 h LYS 78 Cb 0.57 -0.08 0.01 0.00 -0.90 0.00 0.00 32.23 31.82 2kw2 h LYS 78 CO 0.04 0.78 -0.42 -0.91 -2.00 0.00 0.00 179.45 176.93 2kw2 h ASN 79 N 0.70 0.51 -0.47 7.07 2.35 -1.45 -1.51 115.58 122.77 2kw2 h ASN 79 Ca 0.13 -0.66 0.09 0.00 -0.55 0.00 0.00 56.30 55.31 2kw2 h ASN 79 Cb 0.47 -0.15 -0.07 0.00 0.05 0.00 0.00 38.32 38.61 2kw2 h ASN 79 CO 0.02 1.08 0.04 0.25 -1.65 0.00 0.00 177.43 177.17 2kw2 h LEU 80 N -0.03 -0.12 -1.52 1.61 5.85 -0.39 -1.24 115.31 119.48 2kw2 h LEU 80 Ca -0.03 0.10 -0.05 0.00 0.84 0.00 0.00 57.88 58.74 2kw2 h LEU 80 Cb 1.08 0.17 -0.01 0.00 0.37 0.00 0.00 40.66 42.27 2kw2 h LEU 80 CO 0.09 -0.03 -0.24 0.00 -0.34 0.00 0.00 178.44 177.92 2kw2 h ALA 81 N 1.40 1.33 -0.15 1.25 0.00 -1.00 -0.62 119.26 121.48 2kw2 h ALA 81 Ca 0.24 -0.22 -0.11 0.00 0.00 0.00 0.00 54.91 54.82 2kw2 h ALA 81 Cb 0.34 -0.04 0.00 0.00 0.00 0.00 0.00 17.79 18.09 2kw2 h ALA 81 CO -0.36 0.30 -0.33 0.00 0.00 0.00 0.00 179.25 178.86 2kw2 h ALA 82 N 1.76 0.24 -0.75 0.00 0.00 -0.64 -1.21 119.26 118.66 2kw2 h ALA 82 Ca -0.00 -0.43 -0.05 0.00 0.00 0.00 0.00 54.91 54.43 2kw2 h ALA 82 Cb 0.52 -0.04 -0.03 0.00 0.00 0.00 0.00 17.79 18.24 2kw2 h ALA 82 CO 0.03 0.29 0.28 0.00 0.00 0.00 0.00 179.25 179.85 2kw2 h ARG 83 N 0.11 1.14 -0.24 0.00 2.47 -0.74 -1.66 114.38 115.46 2kw2 h ARG 83 Ca 0.00 -0.22 -0.12 0.00 -1.26 0.00 0.00 59.98 58.38 2kw2 h ARG 83 Cb 0.94 -0.18 -0.00 0.00 -1.65 0.00 0.00 29.97 29.07 2kw2 h ARG 83 CO 0.07 0.94 -0.32 0.82 0.56 0.00 0.00 179.97 182.04 2kw2 h ILE 84 N 1.11 1.32 -0.91 2.04 2.04 -1.18 -1.80 117.51 120.12 2kw2 h ILE 84 Ca 0.25 -1.51 0.13 0.00 1.00 0.00 0.00 64.86 64.73 2kw2 h ILE 84 Cb 0.24 1.72 -0.07 0.00 -0.74 0.00 0.00 36.82 37.97 2kw2 h ILE 84 CO -0.02 0.48 0.58 -0.78 0.00 0.00 0.00 178.15 178.41 2kw2 h ASP 85 N 0.35 0.72 -0.31 1.72 3.58 -1.07 -0.06 116.42 121.35 2kw2 h ASP 85 Ca 0.03 0.04 -0.07 0.00 0.42 0.00 0.00 57.03 57.45 2kw2 h ASP 85 Cb 0.90 -0.10 -0.01 0.00 1.72 0.00 0.00 39.33 41.84 2kw2 h ASP 85 CO 0.08 0.37 -0.06 -0.08 -2.88 0.00 0.00 179.24 176.67 2kw2 h GLU 86 N 0.77 0.59 -0.54 0.28 4.22 -1.07 -1.93 114.58 116.89 2kw2 h GLU 86 Ca 0.45 -0.22 -0.06 0.00 0.08 0.00 0.00 59.36 59.62 2kw2 h GLU 86 Cb 0.65 -0.04 -0.02 0.00 0.50 0.00 0.00 28.75 29.84 2kw2 h GLU 86 CO -0.22 0.77 0.12 -0.07 -2.18 0.00 0.00 179.01 177.43 2kw2 h LEU 87 N 0.37 0.84 -0.75 1.64 3.38 -0.58 -1.60 115.31 118.61 2kw2 h LEU 87 Ca 0.08 -0.24 -0.12 0.00 0.09 0.00 0.00 57.88 57.69 2kw2 h LEU 87 Cb 0.54 -0.22 -0.02 0.00 0.09 0.00 0.00 40.66 41.05 2kw2 h LEU 87 CO 0.03 0.86 -0.59 -0.37 0.09 0.00 0.00 178.44 178.45 2kw2 h VAL 88 N 0.77 1.36 -0.54 1.22 -1.51 -1.07 -2.81 116.25 113.68 2kw2 h VAL 88 Ca 0.17 -2.08 -0.11 0.00 -1.23 0.00 0.00 66.70 63.45 2kw2 h VAL 88 Cb 0.36 2.14 -0.02 0.00 -2.13 0.00 0.00 31.29 31.64 2kw2 h VAL 88 CO 0.00 0.58 -0.09 0.00 -1.23 0.00 0.00 177.57 176.83 2kw2 h ALA 89 N 1.41 0.73 -0.58 5.19 0.00 -1.19 -2.95 119.26 121.88 2kw2 h ALA 89 Ca -0.01 -0.34 -0.02 0.00 0.00 0.00 0.00 54.91 54.54 2kw2 h ALA 89 Cb 1.09 -0.19 -0.03 0.00 0.00 0.00 0.00 17.79 18.66 2kw2 h ALA 89 CO 0.08 0.64 0.28 0.00 0.00 0.00 0.00 179.25 180.25 2kw2 h ALA 90 N 0.92 1.41 -0.03 0.00 0.00 -1.04 0.20 119.26 120.73 2kw2 h ALA 90 Ca 0.14 -0.12 -0.16 0.00 0.00 0.00 0.00 54.91 54.78 2kw2 h ALA 90 Cb 0.66 -0.24 -0.01 0.00 0.00 0.00 0.00 17.79 18.20 2kw2 h ALA 90 CO 0.05 0.47 -0.70 1.57 0.00 0.00 0.00 179.25 180.64 2kw2 h LYS 91 N 0.81 0.14 0.00 0.00 2.10 -1.56 -2.74 116.57 115.32 2kw2 h LYS 91 Ca 0.20 -0.12 -0.00 0.00 -2.00 0.00 0.00 60.65 58.73 2kw2 h LYS 91 Cb 0.08 0.02 -0.00 0.00 -0.90 0.00 0.00 32.23 31.43 2kw2 h LYS 91 CO -0.03 0.78 -0.02 0.78 -2.00 0.00 0.00 179.45 178.97 2kw2 h GLY 92 N 1.76 0.00 1.98 0.07 0.00 -1.22 -3.29 103.07 102.37 2kw2 h GLY 92 Ca -0.02 0.00 -0.06 0.00 0.00 0.00 0.00 47.33 47.25 2kw2 h GLY 92 CO 0.10 0.00 -0.28 0.00 0.00 0.00 0.00 176.54 176.36 2kw2 h ALA 93 N 1.98 1.50 -0.93 3.60 0.00 -0.30 -1.73 119.26 123.38 2kw2 h ALA 93 Ca -0.00 -0.27 0.23 0.00 0.00 0.00 0.00 54.91 54.88 2kw2 h ALA 93 Cb 0.59 -0.05 -0.06 0.00 0.00 0.00 0.00 17.79 18.26 2kw2 h ALA 93 CO 0.00 0.37 0.63 -0.07 0.00 0.00 0.00 179.25 180.18 2kw2 h LEU 94 N 0.03 0.31 -8.07 0.00 3.38 -1.66 -3.29 115.31 106.00 2kw2 h LEU 94 Ca 0.00 0.04 -0.76 0.00 0.09 0.00 0.00 57.88 57.25 2kw2 h LEU 94 Cb 0.52 -0.02 -0.24 0.00 0.09 0.00 0.00 40.66 41.01 2kw2 h LEU 94 CO 0.04 0.11 -0.16 -1.61 0.09 0.00 0.00 178.44 176.90 2kw2 s GLU 95 N -5.32 3.05 0.51 1.13 2.02 -0.65 -4.93 118.70 114.51 2kw2 s GLU 95 Ca -0.07 -1.74 0.24 0.00 0.02 0.00 0.00 54.97 53.41 2kw2 s GLU 95 Cb 0.23 -4.31 1.36 0.00 0.10 0.00 0.00 34.13 31.50 2kw2 s GLU 95 CO 0.78 -1.35 2.06 0.45 0.02 0.00 0.00 175.26 177.23 2kw2 h HIS 96 N 8.82 0.00 -2.03 1.61 3.86 -1.78 -3.41 115.15 122.21 2kw2 h HIS 96 Ca -0.26 0.00 0.05 0.00 -1.16 0.00 0.00 60.37 59.00 2kw2 h HIS 96 Cb 1.09 0.00 -0.21 0.00 1.06 0.00 0.00 27.41 29.36 2kw2 h HIS 96 CO 0.77 0.13 -0.09 -1.58 0.86 0.00 0.00 177.93 178.02 2kw2 s HIS 97 N -4.35 -1.21 0.05 2.45 5.65 -1.26 -5.13 115.29 111.48 2kw2 s HIS 97 Ca -0.03 2.22 -0.30 0.00 0.25 0.00 0.00 55.06 57.19 2kw2 s HIS 97 Cb 0.14 0.72 -0.08 0.00 -1.18 0.00 0.00 32.58 32.18 2kw2 s HIS 97 CO 0.61 -0.61 1.68 -1.58 -0.65 0.00 0.00 174.74 174.19 2kw2 s HIS 98 N 2.41 2.28 0.84 3.88 2.46 -1.26 -4.97 115.29 120.93 2kw2 s HIS 98 Ca -0.07 0.25 -0.11 0.00 0.47 0.00 0.00 55.06 55.59 2kw2 s HIS 98 Cb -0.09 -3.98 0.10 0.00 -0.13 0.00 0.00 32.58 28.48 2kw2 s HIS 98 CO -0.19 -3.99 1.14 -1.01 -2.47 0.00 0.00 174.74 168.22 2kw2 s HIS 99 N 2.95 2.01 -1.05 3.88 3.76 -1.26 -3.62 115.29 121.96 2kw2 s HIS 99 Ca 0.75 1.69 0.00 0.00 -0.15 0.00 0.00 55.06 57.35 2kw2 s HIS 99 Cb -0.39 -3.27 0.00 0.00 1.11 0.00 0.00 32.58 30.03 2kw2 s HIS 99 CO 0.33 -2.43 0.00 0.72 -0.85 0.00 0.00 174.74 172.50 2kw2 n HIS 100 N -3.74 -0.45 -0.57 1.40 8.25 -1.26 -5.27 115.22 113.57 2kw2 n HIS 100 Ca 0.11 0.00 0.00 0.00 -0.26 0.00 0.00 57.72 57.57 2kw2 n HIS 100 Cb 0.52 -2.58 0.00 0.00 1.12 0.00 0.00 29.99 29.05 2kw2 n HIS 100 CO 0.00 0.00 0.00 0.72 0.64 0.00 0.00 176.34 177.70