data_AVS_bmrb_pdb_report_17762


save_AVS_chem_shift_analysis
    _AVS_report.Sf_category     AVS_report 
    _AVS_report.Sf_framecode    AVS_chem_shift_analysis 
    _AVS_report.Entry_ID        17762 
    _AVS_report.ID              1 
    _AVS_report.Software_ID     1 
    _AVS_report.Software_label $AVS 

    loop_
        _AVS_analysis.Assembly_ID 
        _AVS_analysis.Entity_assembly_ID 
        _AVS_analysis.Entity_ID 
        _AVS_analysis.Comp_index_ID 
        _AVS_analysis.Comp_ID 
        _AVS_analysis.Comp_overall_assignment_score 
        _AVS_analysis.Comp_typing_score 
        _AVS_analysis.Comp_SRO_score 
        _AVS_analysis.Comp_1H_shifts_analysis_status 
        _AVS_analysis.Comp_13C_shifts_analysis_status 
        _AVS_analysis.Comp_15N_shifts_analysis_status 
        _AVS_analysis.SRO_rule_break 
        _AVS_analysis.SRO_rule_break_probability 
        _AVS_analysis.Entry_ID 
        _AVS_analysis.AVS_report_ID 

        1 1 1 10 ARG Anomalous Consistent Consistent Suspicious Consistent Anomalous . . 17762 1 
        1 1 1 80 ARG Anomalous Consistent Consistent Consistent Consistent Anomalous . . 17762 1 
        1 1 1 85 ARG Anomalous Consistent Consistent Consistent Consistent Anomalous . . 17762 1 
    stop_


    loop_
        _AVS_analysis.Assembly_ID 
        _AVS_analysis.Entity_assembly_ID 
        _AVS_analysis.Entity_ID 
        _AVS_analysis.Comp_index_ID 
        _AVS_analysis.Comp_ID 
        _AVS_analysis.Atom_ID 
        _AVS_analysis.Observed_chem_shift 
        _AVS_analysis.Observed_chem_shift_typing 
        _AVS_analysis.Stat_chem_shift_expected 
        _AVS_analysis.Stat_chem_shift_std 
        _AVS_analysis.Stat_chem_shift_chi_sqr 
        _AVS_analysis.Entry_ID 
        _AVS_analysis.AVS_report_ID 

        1 1 1 10 ARG CA   56.663 .  56.77 2.31 9.6306e-01 17762 1 
        1 1 1 10 ARG CB   27.683 .  30.7  1.83 9.9223e-02 17762 1 
        1 1 1 10 ARG CG   29.440 .  27.21 1.2  6.3122e-02 17762 1 
        1 1 1 10 ARG CD   40.563 .  43.16 0.88 3.1661e-03 17762 1 
        1 1 1 10 ARG H     8.323 .   8.24 0.61 8.9177e-01 17762 1 
        1 1 1 10 ARG HA    4.197 .   4.3  0.46 8.2282e-01 17762 1 
        1 1 1 10 ARG HB2   2.003 .   1.79 0.27 4.3018e-01 17762 1 
        1 1 1 10 ARG HG2   1.857 .   1.57 0.27 2.8780e-01 17762 1 
        1 1 1 10 ARG HD2   3.227 .   3.12 0.24 6.5572e-01 17762 1 
        1 1 1 10 ARG HE    9.679 S   7.4  0.63 2.9751e-04 17762 1 
        1 1 1 10 ARG N   120.914 . 120.8  3.68 9.7529e-01 17762 1 
        1 1 1 10 ARG NE  113.575 A  84.63 1.68 1.6045e-66 17762 1 
        1 1 1 80 ARG CA   54.907 .  56.77 2.31 4.1996e-01 17762 1 
        1 1 1 80 ARG CB   27.391 .  30.7  1.83 7.0576e-02 17762 1 
        1 1 1 80 ARG CG   24.765 .  27.21 1.2  4.1600e-02 17762 1 
        1 1 1 80 ARG CD   40.856 .  43.16 0.88 8.8400e-03 17762 1 
        1 1 1 80 ARG H     9.508 .   8.24 0.61 3.7646e-02 17762 1 
        1 1 1 80 ARG HA    4.376 .   4.3  0.46 8.6877e-01 17762 1 
        1 1 1 80 ARG HB2   1.869 .   1.79 0.27 7.6983e-01 17762 1 
        1 1 1 80 ARG HG2   1.706 .   1.57 0.27 6.1447e-01 17762 1 
        1 1 1 80 ARG HD2   3.131 .   3.12 0.24 9.6344e-01 17762 1 
        1 1 1 80 ARG HE    7.336 .   7.4  0.63 9.1908e-01 17762 1 
        1 1 1 80 ARG N   122.767 . 120.8  3.68 5.9299e-01 17762 1 
        1 1 1 80 ARG NE  115.526 A  84.63 1.68 1.5660e-75 17762 1 
        1 1 1 85 ARG CA   52.272 .  56.77 2.31 5.1512e-02 17762 1 
        1 1 1 85 ARG CB   30.903 .  30.7  1.83 9.1167e-01 17762 1 
        1 1 1 85 ARG CG   24.756 .  27.21 1.2  4.0855e-02 17762 1 
        1 1 1 85 ARG CD   40.856 .  43.16 0.88 8.8400e-03 17762 1 
        1 1 1 85 ARG H     8.204 .   8.24 0.61 9.5294e-01 17762 1 
        1 1 1 85 ARG HA    5.412 .   4.3  0.46 1.5632e-02 17762 1 
        1 1 1 85 ARG HB2   1.994 .   1.79 0.27 4.4992e-01 17762 1 
        1 1 1 85 ARG HG2   1.700 .   1.57 0.27 6.3017e-01 17762 1 
        1 1 1 85 ARG HD2   3.261 .   3.12 0.24 5.5687e-01 17762 1 
        1 1 1 85 ARG HE    7.790 .   7.4  0.63 5.3589e-01 17762 1 
        1 1 1 85 ARG N   122.200 . 120.8  3.68 7.0362e-01 17762 1 
        1 1 1 85 ARG NE  115.659 A  84.63 1.68 3.6247e-76 17762 1 
    stop_


    loop_
        _AVS_analysis.Assembly_ID 
        _AVS_analysis.Entity_assembly_ID 
        _AVS_analysis.Entity_ID 
        _AVS_analysis.Comp_index_ID 
        _AVS_analysis.Comp_ID 
        _AVS_analysis.PRTL_comp_type 
        _AVS_analysis.PRTL_probability_score 
        _AVS_analysis.Entry_ID 
        _AVS_analysis.AVS_report_ID 

        1 1 1 10 ARG CYS 0.84 17762 1 
        1 1 1 10 ARG LYS 0.11 17762 1 
        1 1 1 10 ARG LEU 0.03 17762 1 
        1 1 1 80 ARG LEU 0.54 17762 1 
        1 1 1 80 ARG CYS 0.24 17762 1 
        1 1 1 80 ARG LYS 0.2  17762 1 
        1 1 1 85 ARG CYS 0.57 17762 1 
        1 1 1 85 ARG LYS 0.37 17762 1 
        1 1 1 85 ARG ALA 0.02 17762 1 
        1 1 1 85 ARG ARG 0.01 17762 1 
    stop_

save_


save_AVS
    _Software.Sf_category   software 
    _Software.Sf_framecode  AVS 
    _Software.Entry_ID      17762 
    _Software.ID            1 
    _Software.Name         "AutoPeak - validate_assignments" 
    _Software.Version       2011-12-10 
    _Software.Details      
;
Original version modified by BMRB to export results in a BMRB STAR format. Changed status "Misassigned" to "Anomalous"
;


    loop_
        _Vendor.Name 
        _Vendor.Address 
        _Vendor.Electronic_address 
        _Vendor.Entry_ID 
        _Vendor.Software_ID 

        "Hunter Moseley"  
;
Center for Advanced Biotechnology and Medicine
Rutgers University
679 Hoes Lane, Piscataway NJ 08854-5638
;
 hunter@cabm.rutgers.edu 17762 1 
    stop_


    loop_
        _Task.Task 
        _Task.Entry_ID 
        _Task.Software_ID 

        "validate protein chemical shift assignments"  17762 1 
    stop_


    loop_
        _Software_citation.Citation_ID 
        _Software_citation.Citation_label 
        _Software_citation.Entry_ID 
        _Software_citation.Software_ID 

        2 $AVS_citation  17762 1 
    stop_

save_


save_AVS_citation
    _Citation.Sf_category    citation 
    _Citation.Sf_framecode   AVS_citation 
    _Citation.Entry_ID       17762 
    _Citation.ID             2 
    _Citation.Class          citation 
    _Citation.PubMed_ID      14872126 
    _Citation.Full_citation 
;
Moseley HN, Sahota G, Montelione GT., Assignment validation software suite 
for the evaluation and presentation of protein resonance assignment data.
J Biomol NMR. 28, 341-55 (2004)
;

    _Citation.Status         published 
    _Citation.Type           journal 
save_